Alto 530 Operating Instructions Manual

Alto upright vacuum operating instructions 530, 530cc
Table of Contents

Advertisement

Quick Links

E
Operating
Instructions
Instrucciones
De Operacion
Instructions
D'Operation
READ THIS BOOK
This book has important information for the use and safe operation of this machine. Failure to read
this book prior to operating or attempting any service or maintenance procedure to your ALTO
machine could result in injury to you or to other personnel; damage to the machine or to other property
could occur as well. You must have training in the operation of this machine before using it. If
operator(s) cannot read English, have this manual explained fully before attempting to operate this
machine.
All directions given in this book are as seen from the operator's position at the rear of the machine.
For new books write to: ALTO U.S. Inc., 2100 Highway 265, Springdale, Arkansas 72764.
Form No. 70069A 7/99
Clarke Technology
530 / 530cc
Upright
Vacuum
Barredoras
Verticales
Balayeuse
Printed in the U.S.A.

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Alto 530

  • Page 1 All directions given in this book are as seen from the operator’s position at the rear of the machine. For new books write to: ALTO U.S. Inc., 2100 Highway 265, Springdale, Arkansas 72764. Form No. 70069A 7/99 Clarke Technology 530 / 530cc Upright Vacuum Barredoras...
  • Page 2: Table Of Contents

    Height Adjustment ... 14 How To Change Disposable Paper Bag ... 16 How To Clean Permanent Bag ... 16 How To Replace Brush Roll Belt ... 18 How To Replace Motor ... 20 Page -2- CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...
  • Page 3: Clarke Technology 530 Upright Vacuum Operator's Manual

    Ajuste De Altura ... 15 Como Cambiar La Bolsa De Papel ... 17 Como Limpiar Bolsa Permanente ... 17 Como Reponer La Baner De Cepillo Girantorio ... 19 Como Reemplazar El Motor ... 21 Page -3- CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...
  • Page 4 Reglage De La Hauteur ... 15 Comment Changer Le Sac De Papier ... 17 Comment Essuyer Le Sac Permanent ... 17 Comment Remplacer La Courroie De La Brosse ... 19 Comment Remplacer Le Moteur ... 21 Page -4- CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...
  • Page 5: Important Safety Instructions

    4. Use only as described in this manual. Use only manufacturer's recommended attachments. 5. Do not use with damaged cord or plug. If vacuum cleaner is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center before using.
  • Page 6: Advertencias

    17. Guarde su barredora en un lugar seco, fresco e interior. 18. No desconecte su barredora jalándola por el cable. Para desconectaria jálela de la clavija. Page -6- ADVERTENCIAS Para reducir el riesgo de fuego, choque eléctrico o heridas: CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...
  • Page 7 á l'ecart des ouvertures et des piéces mobiles. 17. Garder láspirateur á l'intérieur dans une aire froide et séche. CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual Pour reduire las risques d'incendie, de choc électrique ou de Page -7-...
  • Page 8: Grounding Instructions

    2. Compruebe que la máquina esté conectada con una caja de enchufe que tiene la configuración adecuada. No utilice ningún adaptador para conectar esta máquina. CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual Improper connection of the Una conexión incorrecta del...
  • Page 9: Instructions Visant La Mise A La Terre

    Broche de mise à la terre Fig. 3 CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual INSTRUCTIONS VISANT LA MISE A LA TERRE Cet appareil doit être mis à la terre. En cas de défaillance ou de panne éventuelles, la mise à la terre fournit au courant un chemin de moindre résistance quI réduit le risque de choc...
  • Page 10 9. Pedal retén manija 10. Bolsa 11. Sostén de la bolsa 12. Cable de 11 metros 13. Clavija aterrizada CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual DIAGRAMME GENERALE LISTE DES PIECES 1. Crochet pour le cordon 2. Tube supérieur de la poignée 3.
  • Page 11: How To Assemble

    Lower Bag Support Connector Figure 4 Knob Figure 5 CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual HOW TO ASSEMBLE CAUTION: Fully assemble the unit before Hardware Package: The package contains two nuts and bolts, one screw and one spring. 1. Assemble Lower Handle...
  • Page 12 Reten perilla para asegurarla. Inserte el resorte superior al para cople gancho (Ver fig. 7) de la bolsa CLARKE TECHNOLOGY 530 Upright Operator's Manual Antes de utilizar su unidad, ensámblela completamente.
  • Page 13: Comment L'assembler

    Piéce pour Support inférieur du recevoir le sac Fig. 8 Bouton Fig. 9 CLARKE TECHNOLOGY 530 Upright Operator's Manual COMMENT L'ASSEMBLER PRECAUTION: Emballage: L'emballage contient deux vis et écrous, une pige et une ressort. 1. Assembler le tube inférieur. Fixen le tube inférieur sur le manchon, aligner les trous et fixet avec la vis et l'écrou inclus dans...
  • Page 14: How To Use

    If the cleaner is difficult to push, follow the procedure and test the cleaner at the next height setting until the unit is comfortable to move. the brush roll must make contact with the carpet for effective cleaning. CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...
  • Page 15: Ajuste De Altura

    Repitalo hasta que le sea cómodo mover la barredora. El cepillo debe estar siempre en contacto con la alfombra para tener una limpieza efectiva. CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual COMMENT L'UTILISER (Fig. 10) 1. Dérouler le fil électrique et brancher á une prise de courant 120V, 60 Hz.
  • Page 16: How To Change Disposable Paper Bag

    Slide lower bag support into slots of bag support guide. Push bag support towards inlet and turn knob to fasten. Insert Spring onto hook. CAUTION: Be sure to clean fan chamber every time you empty permanent bag. CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...
  • Page 17: Como Cambiar La Bolsa De Papel

    PRECAUCION: Asegúrese de limpiar la entrada de la barredora cada vez que vacie la bolsa permanente. CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual COMMENT CHANGER LE SAC DE PAPIER Comment changer le dac de papier (Accessoire Optionel - page 7, #4) Debranchér l'appareil avant de changer le sac.
  • Page 18: How To Replace Brush Roll Belt

    High side of belt Posicion alta de la banda Position haute de la courroie CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual brush roll belt could cause carpet cleaner damage. hold the machine down to avoid tilting.
  • Page 19: Comment Remplacer La Courroie De La Brosse

    (Fig. 14). Gire el cepillo para asegurarse que la banda esté colocada correctamente. CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual COMMENT REMPLACER LA COURROIE DE LA BROSSE NOTE: Eteindre l'appareil et la débroncher avant de changer la counroie, peut s'echauffer pendant l'unage normal.
  • Page 20: How To Replace Motor

    15. Remove screws (15, 16, 17, 18). 16. Disconnect cord from switch. 17. Disconnect connector. 18. Remove motor (fig. 11). 19. Replace new motor. To assemble machine, follow above steps in a reverse order. CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...
  • Page 21: Como Reemplazar El Motor

    18. Quite el motor (fig. 11). 19. Instale el nuevo motor y arme su barredora siguiendo los pasos anteriores en sentido inverso. CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual COMMENT REMPLACER LE MOTEUR IMPORTANT: débranchez l'appareil avant de remplacer le moteur.
  • Page 22 NOTES...
  • Page 23 ALTO U. S. A. Locations HEAD OFFICE ALTO U.S. Inc., St. Louis, Missouri 16253 Swingley Ridge Road, Suite 200 Chesterfield, Missouri 63017-1725 PRODUCTION FACILITIES ALTO U.S. Inc., Springdale, Arkansas 2100 Highway 265 Springdale, Arkansas 72764 (501) 750-1000 Customer Service - 1-800-253-0367 Technical Service - 1-800-356-7274 ALTO U.S.
  • Page 24 CLARKE TECHNOLOGY WARRANTY This Clarke Technology Industrial/Commercial Product is warranted to be free from defects in materials and workmanship under normal use and service for a period of one year from the date of purchase, when operated and maintained in accordance with Clarke Technology's Maintenance and Operations instructions. This warranty is extended only to the original purchaser for use of the product.
  • Page 25: Repair Parts

    530 / 530cc Repair Parts List Upright Vacuum READ THIS BOOK This book has important information for the use and safe operation of this machine. Failure to read this book prior to operating or attempting any service or maintenance procedure to your ALTO machine could result in injury to you or to other personnel;...
  • Page 26 Final Test for Product Safety ... 3 Replacement Procedures ... 3 To Disassemble the Motor ... 4 530 Upright Vacuum External Parts ... 5 530 Upright Vacuum Internal Parts ... 6 530 Upright Motor Assembly ... 8 Trouble Shooting Guide ... 9 Wiring Diagram ...
  • Page 27: Final Test For Product Safety

    FINAL TEST FOR PRODUCT SAFETY At the completion of any repairs the product should be electrically tested for running and electric strength as follows: Electric Strength 1. Set hi-pot test meter to 1500 volts. 2. Product switch to ON-position. 3. Touch one probe of tester to one blade of power cord plug and touch other probe to handle tube.
  • Page 28: To Disassemble The Motor

    (1). 6. Remove field and armature and replace as required. 7. Reassemble in reverse order making sure the field springs (10-M), the ground washer (16-M) and the ground lead are in correct position. CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...
  • Page 29: 530 Upright Vacuum External Parts

    50056A Star Washer, #10 x .204 50057A Bag Support 85307A Screw, #10-32 x CLARKE TECHNOLOGY 539 Upright Vacuum Operator's Manual CLARKE TECHNOLOGY 530 Upright Vacuum External Parts 7/99 24 25 26 36 36A 36B Ref. Part No. 50058A 50059A 50060A...
  • Page 30: 530 Upright Vacuum Internal Parts

    Page -6- 530 Upright Vacuum Internal Parts 7/99 CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...
  • Page 31 53A 50211A Bearing Support Gasket 53B 50212A Bearing Support 53C 50213A Bearing Support Felt CLARKE TECHNOLOGY 539 Upright Vacuum Operator's Manual CLARKE TECHNOLOGY 530 Upright Vacuum Internal Parts 7/99 Part No. Description 50081A Air Duct Gasket 50082A Right Air Duct...
  • Page 32: 530 Upright Motor Assembly

    Field Assembly 120v 52090Au Field Assembly 230v 50228A Spring 50229A Motor Base with Gasket 11B 50231A Motor Base Gasket 50232A Rocker Switch 50233A 50234A Belt Pulley Nut 50235A Ground Washer CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual indicates a change has taken...
  • Page 33: Trouble Shooting Guide

    Brush roll vibrates. 1) Ball bearing worn out. 2) Ball bearing holder damaged. CLARKE TECHNOLOGY 539 Upright Vacuum Operator's Manual POSSIBLE CAUSE CLARKE TECHNOLOGY 530 Upright Vacuum Wiring Diagram 8/98 SOLUTION 1) Check attachement plug. 2) Replace switch. 3) Replace cord.
  • Page 34 Clamp 50812A Cup Gasket 50813A Cup Assembly 50814A Upper Hose Seal 50815A Exhaust Hose 619221 Cable Tie 50816A Dust Cup Hose 50078A Bag Coupling Gasket Asm. 50080A Bag Coupling 50079A Bag Coupling Gasket CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...
  • Page 35 ALTO U. S. A. Locations HEAD OFFICE ALTO U.S. Inc., St. Louis, Missouri 16253 Swingley Ridge Road, Suite 200 Chesterfield, Missouri 63017-1725 PRODUCTION FACILITIES ALTO U.S. Inc., Springdale, Arkansas 2100 Highway 265 Springdale, Arkansas 72764 (501) 750-1000 Customer Service - 1-800-253-0367 Technical Service - 1-800-356-7274 ALTO U.S.
  • Page 36 ALTO U.S. Inc., 2100 Highway 265, Springdale, Arkansas 72764. CLARKE TECHNOLOGY reserves the right to make changes or improvements to its machine without notice. Always use genuine Clarke Technology Parts for repair. CLARKE TECHNOLOGY 2100 Highway 265 Springdale, Arkansas, 72764 CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual...