The external alarm commands in the Command Line Interface (CLI) are listed (along with the appropriate parameters) in the
following table.
Command
show external_alarm
config external_alarm
Each command is listed, in detail, in the following sections.
show external_alarm
Purpose
Used to display the current external alarm status on the Switch.
Syntax
show external_alarm
Description
This command is used to display the current external alarm status on the Switch.
Parameters
None.
Restrictions
None.
Example usage:
To display the current external alarm on the Switch:
DAS-3626:admin#show external_alarm
Command: show external_alarm
Channel
Status
-----------
---------
1
Normal
2
Normal
3
Normal
4
Normal
CTRL+C ESC q
Quit
config external_alarm
Purpose
Used to configure the external alarm prompt messages on the Switch.
Syntax
config external_alarm channel <value 1-4> message <sentence 1-128>
Description
This command is used to set the message to be displayed on console when external alarm
occurs.
Parameters
channel – used to select one of the 4 channels
message – prompt message
Restrictions
Only Administrator and Operator-level users can issue this command.
DAS-3600 Series Ethernet over VDSL Switch CLI Reference Manual
Parameters
channel <value 1-4> message <sentence 1-128>
Alarm Message
--------------------------------------
External Alarm 1 Occurred!
External Alarm 2 Occurred!
External Alarm 3 Occurred!
External Alarm 4 Occurred!
SPACE n
Next Page
E
XTERNAL
p
Previous Page
r
84