1. Open the front panel.
2. Remove the wiring cover.
3. Fix the mains cord to the terminal
board (as shown).
4. Guide the mains cord through the
hole at the back of the indoor unit.
5. Install the cord anchorage and
wiring cover.
6. Close the front panel.
NOTE
The electrical wiring between the
indoor unit and the outdoor unit must
be connected by a qualified
electrician.
Tighten the terminal screws tightly.
After tightening the screws, pull the
wire slightly to confirm whether it's
firm or not.
Make sure that the electrical
connections are properly grounded to
prevent electric shock.
Connective pipe installation
1. For the left-hand and right-hand
piping, remove the pipe cover from
the side panel.
2. For the right back and left back piping,
install the piping as shown.
NOTE
This unit have a both sides drainage
structure, it can be choosen for right, left
or both sides drainage connection. If
choosing both sides drainage
connection, another proper drain hose is
needed as there is only one drain hose
offered by factory. If choosing one side
drainage connection, make sure the
drain hole on the other side is well
plugged. For 9k/12k models, if choosing
right side drainage connection, please
choosing right-hand or right-back piping.
The connection of the drain hose is
supposed to be done by qualified
installer in case of water leakage.
Cover for the
right piping
Right back piping
Move and tape the drain hose with
piping in a position as mentioned in Fig.
above.
Left back piping
Right piping
Left piping
3. Bundle the tubing, connecting cable,
and drain hose with tape securely,
evenly as shown in Figure below.
CAUTION
Connect the indoor unit first, then the
outdoor unit.
Do not allow the piping to let out from
the back of the indoor unit.
Be careful not to let the drain hose
slack.
Heat insulation should be done to the
extension drain hose of indoor unit.
ENGLISH
20
Cover for the
left piping

Advertisement

Table of Contents