Useful Feature

In the eco operation mode, the unit automatically pauses when the air in the room is clean in order to save
money on electricity. Furthermore, if this state continues for longer than 8 hours, the unit automatically
stops operation. (During humidifying operations, the unit will not pause at a certain humidity level.)
Normal automatic operation
When the air is clean, the unit continuously operates
using "Silent" airflow. (In the strong deodorization
mode, the airflow rate is set to "Low".)

Eco operation

When the air is clean and the "Silent" operation
continues for 10 minutes or longer, the fan stops for
about 50 minutes and the unit intermittently operates
using "Silent" airflow for about 10 minutes.
If this state continues for longer than 8 hours, the unit
automatically stops operation.
The degree of air contamination is detected by the odor sensor and dust sensor during eco operation. If the sensors detect
odor or dust, the airflow rate switches according to the degree of air contamination. When the air becomes clearer and the
unit runs for 10 consecutive minutes or longer using "Silent" airflow, the unit starts intermittent operation.
Press
The mode is set to the eco operation.
Note
When using the unit together with the Hitachi air purifier with ionizing function
Pressing the
button on the remote controller in front of the Hitachi air purifier with ionizing function (model whose
ionization setting / release is switched using the remote controller) sets and releases ionization. Furthermore, pressing
the ionizing button on the remote controller of the model with the ionizing function sets and releases eco operation.
If you feel uncomfortable about indicator lightings when you go to sleep, press
for 3 seconds or longer to dim the indicators.
Eco Operation
button.

Dimmer Control

Ai r
Sensor
r
Silent
operation
Stop
10 minutes
10 minutes
Silent
operation
50 minutes
Stop
"eco" indicator lights up.
Pollen
Air Purify
Auto
How to set/cancel
Every time you press the
"Cancel" will alternate.
The settings are stored.
Press
button for 3 seconds or
longer.
The indicators are dimmed.
How to set/cancel
Every time you press the
three seconds, "Set" and "Cancel" will alternate.
The setting will be saved in memory.
10 minutes
50 minutes
Strong
Skin
Deodorization
Humidify
Moisturize
On
Max(Blinking)
button, "Set" and
button on the unit
button for approximately
E-21