HOST
HOST
RS-422
INTERFACE
W26
DPS 6/LEVEL 6
PRU7070/
JI
7075
PRINTER
1-_--L _ _ _
---I,....-----
4000 FT MAX - - - - - - ; -..... L-_ _ _ _ --J
RS-422 DIRECT CONNECT
HOST CABLE
HOST
HOST
MODEM
INTERFACE
MODEM CABLE
50FTMAX
UNIVERSAL
MODEM
BYPASS
UNIVERSAL
MODEM
BYPASS
DCF6927 UNIVERSAL BYPASS CONNECT
HOST
HOST
MODEM
INTERFACE
HOST CABLE
MODEM CABLE
50FTMAX
RS-232-C REMOTE CONNECT
Figure B-1. Host-Printer Connection
Direct Connection
Direct connection can be accomplished in two ways:
RS-422-A balanced direct
Universal modem bypass
PRINTER CABLE 25 FT
15 PIN/25 PIN CROSSOVER
PRU7071/
J1
7076
PRINTER
MODEM CABLE
50FTMAX
J1
PRU7071/
7076
PRINTER
MODEM CABLE
50FTMAX
The RS-232-C direct connect enables local communications up to a distance of
50 feet. The RS-422-A balanced direct connect enables local communication up
to 4000 feet at data rates up to 19,200 bits per second.
The universal modem bypass (DCF6927) is a self-contained, stand-alone device
enabling local communications over a distance of up to 2500 feet over ordinary
telephone cable. It is designed as an inexpensive replacement for a modem
over this limited distance.