Cd Adjustment - Pioneer AVH-P6400CD UC Service Manual

Hide thumbs Also See for AVH-P6400CD UC:
Table of Contents

Advertisement

1

6.6 CD ADJUSTMENT

QQ
3 7 63 1515 0
1) Precautions
• This unit uses a single power supply (+5V) for the reg-
ulator. The signal reference potential, therefore, is
connected to VREF(approx. 2.1V) instead of GND.
If VREF and GND are connected to each other by mis-
A
take during adjustments, not only will it be impossi-
ble to measure the potential correctly, but the servo
will malfunction and a severe shock will be applied to
the pick-up. To avoid this, take special note of the fol-
lowing.
Do not connect the negative probe of the measuring
equipment to VREF and GND together. It is especially
important not to connect the channel 1 negative
probe of the oscilloscope to VREF with the channel 2
negative probe connected to GND.
Since the frame of the measuring instrument is usual-
ly at the same potential as the negative probe, change
the frame of the measuring instrument to floating sta-
tus.
If by accident VREF comes in contact with GND,
immediately switch the regulator or power OFF.
• Always make sure the regulator is OFF when connect-
B
ing and disconnecting the various filters and wiring
required for measurements.
• Before proceeding to further adjustments and mea-
surements after switching regulator ON, let the player
run for about one minute to allow the circuits to stabi-
lize.
TE
L 13942296513
• Since the protective systems in the unit's software are
rendered inoperative in test mode, be very careful to
avoid mechanical and /or electrical shocks to the sys-
tem when making adjustment.
• The RFI and RFO signals are easy to oscillate because
of a wide band. When observing them, insert a resis-
tor of about 1 kΩ to the series.
• This equipment will not guarantee the load ejection
C
operation when the mechanical unit is turned upside
down. In particular, if the ejection operation is incor-
rectly performed and recovery is disabled, the recov-
ery is enabled by resetting a product or turning ACC
off to on.
www
D
90
1
http://www.xiaoyu163.com
2
x
ao
y
.
i
AVH-P6400CD/UC
2
http://www.xiaoyu163.com
3
8
2) Test Mode
This mode is used for adjusting the CD mechanism
module of the device.
• Test mode starting procedure
Acc ON(or detach grille on) and reset while pressing
the ANGLE+ and BAND keys together.
• Test mode cancellation
Switch ACC, back-up OFF.
• After pressing the EJECT key, do not press any other
key until the disk is completely ejected.
• If the ] or [ key is pressed while focus search is in
progress, immediately turn the power off (otherwise
the actuator may be damaged due to adhesion of the
lenses).
• Jump operation of TRs other than 100TR continues
after releasing the key. CRG move and 100TR jump
operations are brought into the "Tracking close" sta-
tus when the key is released.
• Powering Off/On resets the jump mode to "1TR", the
RF AMP gain setting to TYP, and the automatic adjust-
ment value to the initial value.
• Please use the "remote control unit of the pr oduct
accessory" after the test mode starts.
Q Q