Clean Air System
If the vacuum switch valve does not operate as described,
replace it with a new one.
To check air flow through the vacuum switch valve, just
blow through the air cleaner hose.
Vacuum Switch Valve Closing Pressure (Open → Close)
57 ∼ 65 kPa (430 ∼ 490 mmHg)
Standard:
High Vacuum [A]
Secondary air cannot flow [B]

Clean Air System Hose Inspection

Be certain that all the hoses are routed without being flat-
tened or kinked, and are connected correctly to the air
cleaner housing, vacuum switch valve, carburetor body,
and cylinder head covers.
If they are not, correct them. Replace them if they are
damaged.
NOTE
ENGINE TOP END 5-11