Redundancy - Code128 before transmitting its data to confirm that there is no additional ISBT
symbol.
Check ISBT Table - The ISBT specification includes a table that lists several types of ISBT bar codes
that are commonly used in pairs. If ISBT128 Concat Mode is set, enable Check ISBT Table to
concatenate only those pairs found in this table. Other types of ISBT codes are not concatenated. A
check in the checkbox indicates that redundancy is enabled (default - disabled).
Security Level - The scanner offers four levels of decode security for Code 128 bar codes. Select
increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship
between security and scanner aggressiveness, so choose only that level of security necessary for any
given application.
Security Level 0 - This setting allows the scanner to operate in its most aggressive state, while
providing sufficient security in decoding most "in-spec" bar codes.
Security Level 1 - This setting eliminates most misdecodes (default).
Security Level 2 - Select this option if Security level 1 fails to eliminate misdecodes.
Security Level 3 - If Security Level 2 is selected and misdecodes still occur, select this security
level. Be advised, selecting this option is an extreme measure against mis-decoding severely out
of spec bar codes. Selecting this level of security significantly impairs the decoding ability of the
scanner. If this level of security is needed, try to improve the quality of the bar codes.
Code39
Length1 - Use to set decode lengths (default - 0). See
information.
Length2 - Use to set decode lengths 4 (default - 55). See
information.
Verify Check Digit - Enable this feature to check the integrity of all Code 39 symbols to verify that the
data complies with a specified check digit algorithm. The digital scanner decodes only those Code 39
symbols that include a modulo 43 check digit. Enable this feature only if the Code 39 symbols contain
a modulo 43 check digit (default - disabled).
Report Check Digit - Transmit Code 39 data with or without the check digit. A check in the checkbox
indicates to send Code 39 data with check digit (default - disabled).
Full ASCII - Code 39 Full ASCII is a variant of Code 39 that pairs characters to encode the full ASCII
character set. To enable or disable Code 39 Full ASCII (default - disabled),
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - disabled).
Convert Code39 To Code32 - Code 32 is a variant of Code 39 used by the Italian pharmaceutical
industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32
(default - disabled).
Report Code32 Prefix - Scan the appropriate bar code to enable or disable adding the prefix
character "A" to all Code 32 bar codes (default - disabled).
Security Level - Options: Security level 0, Security Level 1, Security Level 2 and Security Level 3
(default - Security level 1).
DataWedge Configuration 4 - 11
Decode Lengths on page 4-14
Decode Lengths on page 4-14
for more
for more