4 - 10 ET1 Enterprise Tablet Integrator Guide
•
UPCA
•
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of
the data. Enables or disables this option. A check in the checkbox indicates that the option is enabled
(default - enabled).
•
Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. There are three options for transmitting a UPCA preamble:
•
Preamble None - Transmit no preamble.
•
Preamble Sys Char - Transmit System Character only (default).
•
Preamble Country and Sys Char - Transmit System Character and Country Code ("0" for USA).
Select the appropriate option to match the host system.
•
UPCE0
•
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of
the data. Enables or disables this option. A check in the checkbox indicates that the option is enabled
(default - disabled).
•
Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. There are three options for transmitting a UPCE0 preamble:
•
Preamble Sys Char - Transmit System Character only.
•
Preamble Country and Sys Char - Transmit System Character and Country Code ("0" for USA).
•
Preamble None - Transmit no preamble (default).
Select the appropriate option to match the host system.
•
Convert UPCE0 To UPCA - Enable to convert UPCE0 (zero suppressed) decoded data to UPC-A
format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A
programming selections. Disable to transmit UPCE0 decoded data as UPCE0 data, without
conversion (default - disabled).
•
Code128
•
Length1 - Use to set decode lengths (default - 0). See
information.
•
Length2 - Use to set decode lengths (default - 55). See
information.
•
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - disabled).
•
Enable Plain Code 128 - Flag to enable other 128 sub types (besides GS1-128 and ISBT-128).
•
Enable GS1-128 - Set the GS1 128 subtype. A check in the checkbox indicates that the option is
enabled (default - enabled).
•
Enable ISBT128 - Set the ISBT128 subtype. A check in the checkbox indicates that the option is
enabled (default - enabled).
•
ISBT128 Concatenation Mode - Select an option for concatenating pairs of ISBT code types:
•
Concat Mode Never - Do not concatenate pairs of ISBT codes encountered (default).
•
Concat Mode Always - There must be two ISBT codes in order to decode and perform
concatenation. Does not decode single ISBT symbols.
•
Concat Mode Auto - Decodes and concatenates pairs of ISBT codes immediately. If only a single
ISBT symbol is present, the device must decode the symbol the number of times set via
Decode Lengths on page 4-14
Decode Lengths on page 4-14
for more
for more