HP 5920 series Configuration Manual page 82

Hide thumbs Also See for 5920 series:
Table of Contents

Advertisement

# Configure Switch A to operate in FCF mode. Create interface VFC 100, bind it to interface
Ten-GigabitEthernet 1/0/2, configure it to operate in E mode, and assign it to VSAN 1 as a trunk
port.
<SwitchA> system-view
[SwitchA] fcoe-mode fcf
[SwitchA] interface Vfc 100
[SwitchA-Vfc100] bind interface Ten-GigabitEthernet1/0/2
[SwitchA-Vfc100] fc mode f
[SwitchA-Vfc100] port trunk vsan 10
[SwitchA-Vfc100] quit
# Enable the fabric configuration function.
[SwitchA] vsan 1
[SwitchA-vsan1] domain configure enable
# Configure the domain ID as 1.
[SwitchA-vsan1] domain-id 1 static
Non-disruptive reconfiguration or isolating the switch may be performed. Continu
e? [Y/N]:y
[SwitchA-vsan1] quit
# Enable FCoE for VLAN 10 and map it to VSAN 1.
[SwitchA] vlan 10
[SwitchA-vlan10] fcoe enable vsan 1
[SwitchA-vlan10] quit
# Configure a static route.
[SwitchA-vsan1] fc route-static 020000 8 Vfc100
Configure Switch B:
2.
# Configure Switch B to operate in FCF mode. Create interface VFC 200, bind it to interface
Ten-GigabitEthernet 1/0/2, configure it to operate in E mode, and assign it to VSAN 1 as a trunk
port.
<SwitchB> system-view
[SwitchB] fcoe-mode fcf
[SwitchA] interface Vfc 200
[SwitchA-Vfc200] bind interface Ten-GigabitEthernet1/0/2
[SwitchA-Vfc200] fc mode f
[SwitchA-Vfc200] port trunk vsan 1
[SwitchA-Vfc200] quit
# Enable the fabric configuration function.
[SwitchB] vsan 1
[SwitchB-vsan1] domain configure enable
# Configure the domain ID as 2.
[SwitchB-vsan1] domain-id 2 static
Non-disruptive reconfiguration or isolating the switch may be performed. Continu
e? [Y/N]:y
[SwitchA-vsan1] quit
# Enable FCoE for VLAN 10 and map it to VSAN 1.
<SwitchA> system-view
[SwitchA] vlan 10
[SwitchA-vlan10] fcoe enable vsan 1
76

Advertisement

Table of Contents
loading

This manual is also suitable for:

5900 series

Table of Contents