GENERAtOR ANd UNIdIRECtIONAL stARtER
Generator and unidirectional starter removal
se-
quen-
Operation/parts to remove
ce
1
Stator coil connector
2
2 Crankshaft position sensor connector
3
3 Neutral switch cable connector
4
Timing mark access screw
5
Crankshaft end access screw
6
7
Generator cover gasket
8
9
Crankshaft position sensor
ENGINE OVERHAUL
Engine oil
Sprocket cover
Generator cover
Dowel pin
New =
part to be replaced upon reassembly
Quantity
1
1
1
1
1
1
1
2
1
F1.30
Remarks
Disconnect.
Disconnect.
Disconnect.
Part. N. 8000 H4704 (07-2010)