(3) Trouble mode (C)
Pilot lamp remains green (red fails to light) after
battery has been connected.
Is ambient temperature
within designated range (between
0˚C and 40˚C) ?
battery very
Are the connection
terminals of the charger
or the battery dirty or
deformed ?
Is the resistance
between (S) and (---) terminals
2KΩ to 100 KΩ ?
Faulty internal circuits
Replace PCB.
YES
Is the
hot ?
NO
NO
YES
NO
Conduct charging within
designated temperature range.
0 ˚C
YES
Allow battery to cool prior to
charging
For EB 2420, charging cannot be accomplished
if battery temperature is above 60˚C.
For EB 2430HA, charging cannot be accomplished
if battery temperature is above 45˚C.
YES
Clean, or repair deformed
terminals.
NO
Replace battery.
17
---
40 ˚C