Wash Thermistor
Test Points
Steam generator Thermistor
Test Points
(tolerance ±5%)
(1) to (2)
(tolerance ±5%)
(1) to (2)
Result
39.5 kΩ
At 104°F (40°C)
26.1 kΩ
At 140°F (60°C)
12.1 kΩ
At 158°F (70°C)
8.5 kΩ
At 203°F (95°C)
3.8 kΩ
At 221°F (105°C)
2.8 kΩ
Result
39.5 kΩ
26.1 kΩ
At 104°F (40°C)
12.1 kΩ
At 140°F (60°C)
8.5 kΩ
At 158°F (70°C)
3.8 kΩ
At 203°F (95°C)
2.8 kΩ
At 221°F (105°C)
2.1 kΩ
At 241°F (116°C)
1.4 kΩ
At 266°F (130°C)
1.0 kΩ
At 293°F (145°C)
0.7 kΩ
At 320°F (160°C)
0.4 kΩ
At 356°F (180°C)
45