Inspect the amplifier during unpacking. If any damage is found, notify your dealer immediately. Be sure to save the carton and all packing materials. Should you ever need to ship the unit back to Peavey Electronics, one of its service centers, or the dealer;...
Page 3
If the fuses open instantly each time you attempt to turn the unit on, it should be taken to a qualified Peavey Service Center for repair.
Page 4
Rear Panel CHANNEL BRIDGE CHANNEL CHANNEL LINE OUTS 40 Hz INPUTS MADE IN CHINA THRU BRIDGE 150 Hz X-OVER STEREO BRIDGE HIGH T 15AL 230V 250V BRIDGE 40 Hz 115V THRU 150 Hz X-OVER ENABLE DEFEAT HIGH MOUNT IN RACK ONLY CHANNEL INSTALLER SUR SUPPORT SPEAKER OUTPUTS...
Page 5
The IN position is DEFEAT; the OUT position is ENABLE. Normally, the DDT function should be enabled to minimize clipping. With this feature defeated, a severe overload could cause the mains circuit breaker to trip. The Peavey DDT compression system will be covered in greater detail later in this manual.
Page 6
When using Bridge mode, the connected enclosure impedance must be 4 or 8 Ohms — never below 4 Ohms. DDT™ Peavey’s patented DDT (Distortion Detection Technique) limiter circuit enables the sound technician to maximize the performance of the amplifier/speaker combination by preventing the power amplifier from clipping. When the onset of clipping is detected, the limiter engages to prevent damage to the loudpeakers and degradation of sound quality.
PV ® 1 PV ® 2 PV ® 3 Specifications RATED OUTPUT POWER @ 120V AC Line: Stereo mode 4 Ohms, 1 kHz, 1% THD 410 W RMS/chan 630 W RMS/chan 1060 W RMS/chan 8 Ohms, 1 kHz, 1% THD 250 W RMS/chan 370 W RMS/chan 630 W RMS/chan...
Page 10
Warranty registration and information for U.S. customers available online at www.peavey.com/warranty or use the QR tag below Features and speci cations subject to change without notice. Peavey Electronics Corporation 5022 Hartley Peavey Drive Meridian, MS 39305 (601) 483-5365 FAX (601) 486-1278 Logo referenced in Directive 2002/96/EC Annex IV (OJ(L)37/38,13.02.03 and defined in EN 50419: 2005...