[B211] ADJUST menu (STD/COL1/COL2)
To start adjustment, proceed as follows.
When you use the previously adjusted values for
adjustment, you can make start adjustment by selecting
START without perform operations step (1) and step
(2).
(1) Select either D65 or D93.
Rather than selecting D65 or D93, you may instead
enter the values of the CIE 1931 color system x
and y coordinates.
(2) Enter values for LOWLIGHT and HIGHLIGHT.
(3) Select START.
START: Start adjustment. ÷[B2111]
X: Enter the x coordinate.
Y: Enter the y coordinate.
LOW LIGHT (20IRE): Enter the luminance (cd/m
for low light.
HIGH LIGHT (100IRE): Enter the luminance (cd/
2
m
) for high light.
D65: Use D65 setting.
D93: Use D93 setting.
[B212] ANALYZE menu (STD/COL1/COL2)
The following message appears. Perform operation
according to the message to enable the BKM-14L to
read the color system and luminace value.
SET PROBE ON THIS CRT
PRESS ENTER
Attach the BKM-14L on the center of the CRT and
press the ENTER button. ÷[B2121]
Once the BKM-14L has carried out calibration, the
BKM-14L can start analyze the monitor's
performance.
[B321] MONITOR ADDRESS menu (STD/COL1/
COL2)
Select STD, COL1 or COL2. ÷ Copy is carried out.
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D93).
COL2: Copy common data (factory setting: D56/
D65
1)
).
......................................................................................................................................................................................
1) D56: BVM-20G1U/14G1U/14G5U
D65: BVM-20G1E/20G1A/14G1E/14G1A/14G5E/14G5A
[B331] FILE NAME menu (STD/COL1/COL2)
Select STD, COL1, or COL2 of the memory card data.
÷ Copy is carried out.
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D93).
COL2: Copy common data (factory setting: D56/
D65
1)
).
[B2111] COLOR TEMP ADJ menu
(STD/COL1/COL2)
The following message appears. Perform operation
according to the message to start adjustment.
SET PROBE ON CRT
PRESS ENTER
Adjustment starts when the probe is placed against the
2
)
center of the screen and the ENTER button is pressed.
[B2121] ANALYZE menu
(STD/COL1/COL2)
Display color temperature and luminance readout
values from the BKM-14L.
X: xxxx: Display the x coordiate of the color system.
Y: xxxx: Display the y coordiate of the color system.
L: xxxx: Display the luminance value.