SERVICE INFORMATION
GENERAL
• Battery fluid level should be checked regularly. Fill with distilled water when necessary.
• Quick charge a battery only in an emergency; slow-charging is preferred.
• Remove the battery from the motorcycle for charging. If the battery must be charged on the motorcycle, disconnect
thr
battery cables.
Do not smoke or allow flames near a charging battery. The gas produced by a battery will explode if flames or sparks
are brought near.
• All charging system components can be tested on the motorcvcle,
SPECIFICATIONS
Battery
Capacity
12V 14AH
Specific gravity
1.280/20°C (68°F)
Charging rate
1.4 amperes maximum
Alternator
Engine speed
1,750 min" (rpm)
4,350 min" (rpm)
Capacity
12.5 A min. (No load)
20 A min. (No load)
Voltage regulator
Transistorized non-adjustable regulator
.TOOL
Special
Rotor puller
07933-2160000
TORQUE VALUE
Alternator rotor bolt
30-38 N·m (3.0-3.8 kg-m, 22-27 ft-Ib]