Changing Port Data Rate - NEC SIGMABLADE N8406-019 User Manual

Fc switch module
Table of Contents

Advertisement

Changing Port Data Rate

After completing login to the console of the FC Switch Module, change the port data rate of each
port on the FC Switch Module according to the procedure below. (The setting is always required.)
The port data rate is fixed to 4G bps for every port when an FC Switch Module is shipped from the f
actory.
1.
Type "portcfgshow" on the console screen.
2.
The current port settings appear.
WH040000350:admin> portcfgshow
Ports of Slot 0
------------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed
Trunk Port
Long Distance
VC Link Init
Locked L_Port
Locked G_Port
Disabled E_Port
ISL R_RDY Mode
RSCN Suppressed
Persistent Disable .. .. ON ON
Ports of Slot 0
------------------+--+--+--+--+----+--+--+--
Speed
Trunk Port
Long Distance
VC Link Init
Locked L_Port
Locked G_Port
Disabled E_Port
ISL R_RDY Mode
RSCN Suppressed
Persistent Disable ON .. .. ..
WH040000350:admin>
Setting at shipment from factory
The port data rate of an FC Switch Module must be set to be the same as
that of fibre channel devices connected to the FC Switch Module. If the port
data rates are different, the connected fibre channel devices cannot link up
to the FC Switch Module. For the port data rate of each fibre channel device
to be connected to the FC Switch Module, refer to the User's Guide of the
fibre channel device.
Any commands used on the switch console should be specified with
lowercase letters.
0
1
2
3
4
4G 4G 4G 4G
4G 4G 4G 4G
ON .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. ON ON ON
ON ON ON ON
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. ON ON ON
16 17 18 19
20 21 22 23
4G 4G 4G 4G
4G 4G 4G 4G
.. ON ON ON
ON ON ON ON
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. ON ON ON
ON .. .. ..
ON .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
where AN:AutoNegotiate, ..:OFF, ??:INVALID.
The port status display also includes the information on the ports
unavailable to N8406-019. However, this is not an error.
5
6
7
8
9 10 11
4G 4G 4G 4G
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
ON ON ON ON
.. .. .. ..
.. .. .. ..
ON ON ON ON
- 118 -
12 13 14 15
4G 4G 4G 4G
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
ON ON ON ON
.. .. .. ..
.. .. .. ..
ON ON ON ON

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigmablade n8406-020

Table of Contents