Fault location

Fault
System
Engine not starting or
Ignition system
with difficulty
Fuel supply
Compression
Mechanical fault
Warm start problems
Engine starts but dies
Fuel supply
Insufficient performance
Several systems may
simultaneously be
affected
Operating time
Item
Engine oil
Tightening parts (bolt, nut)
Fuel tank
Throttle lever
Stop switch
Low-speed rotation
Air cleaner
Ignition plug
Cooling air duct
Fuel pipe
Fuel filter
Clearance between air intake
valve and air discharge valve
Oil tube
Engine overhaul
Carburetor
*1 Perform initial replacement after 20h operation.
*2 For the 200 operating hour inspection, request Authorized Service Agent or a machine shop.
*3 After emptying the fuel tank, continue to run the engine and drain fuel in the carburetor.
Observation
Ignition spark O.K.
No ignition spark
Fuel tank filled
No compression when
pulled over
Starter not engaging
Tank filled ignition spark
existing
Tank filled
Engine idling poor
Before
operation
Inspect/clean
Replace
Inspect
Clean/inspect
Drain fuel
Check function
Check function
Inspect/adjust
Clean
Inspect
Clean/inspect
Inspect
Replace
Clean/replace
Adjust
Inspect
Drain fuel
Cause
Fault in fuel supply or compression system, mechanical
defect
STOP-switch operated, wiring fault or short circuit, spark plug
or connector defective, ignition module faulty
Incorrect choke position, carburetor defective, fuel supply
line bent or blocked, fuel dirty.
Cylinder bottom gasket defective, crankshaft seals damaged,
cylinder or piston rings defective or improper sealing of spark
plug
Broken starter spring, broken parts inside of the engine
Carburetor contaminated, have it cleaned
Incorrect idling adjustment, carburetor contaminated
Fuel tank vent defective, fuel supply line interrupted, cable or
STOP-switch faulty
Air filter contaminated, carburetor contaminated, muffler
clogged, exhaust duct in the cylinder clogged