DVP-NS30/NS32/NS33/NS52P
QQ
3 7 63 1515 0

7-2. ADJUSTMENT OF VIDEO SYSTEM

1.
Checking Video Level
<Purpose>
Checking Video Level the NTSC/PAL standard, and if not correct,
the brightness will be too large or small.
Mode
HLX-504
Signal
Color bars 100%
Test point
LINE OUT (VIDEO) connector
(75 Ω terminated)
Instrument
Oscilloscope
Specification
1.0 ± 0.08 Vp-p
Adjusting method:
1)
In the Video Signal menu "1" Color Bar 100% play back.
2)
Confirm that the Video Level is 1.0 ± 0.08 Vp-p.
2.
Checking Progressive Video Output Level
<Purpose>
Check progressive video output level. If it is incorrect, correct
TE
brightness will not be attained when connected to, for instance,
L 13942296513
projector.
Mode
HLX-504
Signal
Color bars 100%
Test point
COMPONENT VIDEO OUT (Y)
connector (75 Ω terminated)
Instrument
Oscilloscope
Specification
1.0 ± 0.08 Vp-p
Adjusting method:
1)
In the Video Signal menu "1" Color Bar 100% play back.
2)
Confirm that the Y level is 1.0 ± 0.08 Vp-p.
www
http://www.xiaoyu163.com
1.0 ± 0.08 Vp-p
Fig. 7-1.
1.0 ± 0.08 Vp-p
Fig. 7-2.
x
ao
y
.
i
http://www.xiaoyu163.com
8
3.
Checking S Video Output S-Y
<Purpose>
Check S-terminal video output. If it is incorrect, pictures will not be
displayed correctly in spite of connection to the TV with a S-terminal
cable.
Mode
Signal
Test point
Instrument
Specification
Checking method:
1)
In the Video Signal menu "1" Color Bar 100% play back.
2)
Confirm that the S-Y level is 1.0 ± 0.08 Vp-p.
4.
Checking S Video Output S-C
<Purpose>
This checks whether the S-C satisfies the NTSC/PAL standard. If it
Q Q
is not correct, the colors will be too dark or light.
3
6 7
1 3
Mode
Signal
Test point
Instrument
Specification
Checking method:
1)
In the Video Signal menu "1" Color Bar 100% play back.
2)
Confirm that the S-C burst is "A".
u163
.
7-2
2 9
9 4
2 8
HLX-504
Color bars 100%
S VIDEO OUT (S-Y) connector
(75 Ω terminated)
Oscilloscope
1.0 ± 0.08 Vp-p
1.0 ±0.08 Vp-p
Fig. 7-3.
1 5
0 5
8
2 9
9 4
HLX-504
Color bars 100%
S VIDEO OUT (S-C) connector
(75 Ω terminated)
Oscilloscope
A = 286 ± 30 mVp-p (NTSC)
A = 300 ± 100 mVp-p (PAL)
A
Fig. 7-4.
m
co
9 9
2 8
9 9

Hide quick links: