Specifications - Makita RP1800 Instruction Manual

Hide thumbs Also See for RP1800:
Table of Contents

Advertisement

ENGLISH (Original instructions)

SPECIFICATIONS

Collet chuck capacity
Plunge capacity
No load speed (min
• Due to our continuing programme of research and development, the specifications herein are subject to change without notice.
• Note: Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
Read instruction manual.
DOUBLE INSULATION
Only for EU countries
Do not dispose of electric equipment
together with household waste material!
In observance of European Directive
2002/96/EC on waste electric and
electronic
implementation in accordance with
national law, electric equipment that
have reached the end of their life must
be collected separately and returned to
an
recycling facility.
Intended use
The tool is intended for flush trimming and profiling of
wood, plastic and similar materials.
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated in accordance with European
Standard and can, therefore, also be used from sockets
without earth wire.
For Model RP1800
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under
Model
-1
)
Overall length
Net weight
Safety class
equipment
and
environmentally
compatible
RP1800 /
RP1800F
22,000
6.0 kg
END201-4
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.40 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected with
a fuse or protective circuit breaker having slow tripping
characteristics.
For Model RP1800F
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
its
fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.39 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected with
a fuse or protective circuit breaker having slow tripping
ENE010-1
characteristics.
For Model RP1801
ENF002-1
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.38 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected with
a fuse or protective circuit breaker having slow tripping
ENF100-1
characteristics.
2
RP1801 /
RP2300FC
RP1801F
12 mm or 1/2"
0 - 70 mm
9,000 - 22,000
312 mm
/II
RP2301FC
6.1 kg
ENF100-1
ENF100-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rp1800fRp1801Rp1801fRp2300fcRp2301fc

Table of Contents