National Instruments NI 784xR User Manual page 20

Ni r series intelligent daq
Hide thumbs Also See for NI 784xR:
Table of Contents

Advertisement

Chapter 1
Introduction
1
Measurement categories, also referred to as installation categories, are defined in electrical safety standard IEC 61010-1.
2
Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation.
3
MAINS is defined as a hazardous live electrical supply system that powers equipment. Suitably rated measuring circuits may
be connected to the MAINS for measuring purposes.
R Series Intelligent DAQ User Manual
Pollution Degree 3 means that conductive pollution occurs, or dry,
nonconductive pollution occurs that becomes conductive due to
condensation.
You must insulate signal connections for the maximum voltage for which
the device is rated. Do not exceed the maximum ratings for the device. Do
not install wiring while the device is live with electrical signals. Do not
remove or add connector blocks when power is connected to the system.
Avoid contact between your body and the connector block signal when hot
swapping modules. Remove power from signal lines before connecting
them to or disconnecting them from the device.
Operate the device at or below the measurement category
hardware label. Measurement circuits are subjected to working voltages
and transient stresses (overvoltage) from the circuit to which they are
connected during measurement or test. Installation categories establish
standard impulse withstand voltage levels that commonly occur in
electrical distribution systems. The following is a description of installation
categories:
Measurement Category I is for measurements performed on circuits
not directly connected to the electrical distribution system referred to
3
as MAINS
voltage. This category is for measurements of voltages
from specially protected secondary circuits. Such voltage
measurements include signal levels, special equipment, limited-energy
parts of equipment, circuits powered by regulated low-voltage sources,
and electronics.
Measurement Category II is for measurements performed on circuits
directly connected to the electrical distribution system. This category
refers to local-level electrical distribution, such as that provided by a
standard wall outlet (for example, 115 AC voltage for U.S. or 230 AC
voltage for Europe). Examples of Measurement Category II are
measurements performed on household appliances, portable tools,
and similar modules.
1-10
1
marked on the
2
ni.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ni 785xrNi 781xrNi 783xr784xrNi r series

Table of Contents