Overview
Shipping Components
This document includes an overview and specifications for the
NI PMA-1115 Portable Monitor Accessory.
The National Instruments PMA-1115 is a monitor and keyboard accessory
for use with NI 8-slot PXI chassis. It includes the following features:
15 in. high-brightness TFT LCD touch screen panel
105-key English keyboard and touchpad
Hardware for mounting to NI 8-slot PXI chassis
Anti-glare tempered glass for LCD protection
VGA and DVI connectivity to the LCD
USB connectivity to the touch screen, keyboard, and touchpad
Sheetmetal construction
Universal AC/DC power supply with Y-cable for single wall
connection
RoHS compliance
For complete PXI system configuration information, refer to
.
pxiadvisor
The NI PMA-1115 kit includes the following items:
NI PMA-1115
Adapter plate and mounting hardware
Y-splitter power cable
12 V DC/AC power adapter
ni.com/

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Portable Monitor Accessory NI PMA-1115 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for National Instruments Portable Monitor Accessory NI PMA-1115

  • Page 1 Portable Monitor Accessory This document includes an overview and specifications for the NI PMA-1115 Portable Monitor Accessory. Overview The National Instruments PMA-1115 is a monitor and keyboard accessory for use with NI 8-slot PXI chassis. It includes the following features: • •...
  • Page 2 • • • • • Mounting The NI PMA-1115 includes a complete mounting kit for attachment to any NI 8-Slot PXI chassis. This kit contains an adapter plate with provisions to relocate the carrying handle as well as all required fasteners. Complete the following instructions to install the NI PMA-1115.
  • Page 3 1 Handle covers 1 M4 × 8 pan-head screws © National Instruments Corporation Figure 2. Removing the Handle Remove the handle from the chassis. Retain the handle. Discard the screws. Attach the adapter plate to the chassis using the supplied M4 × 8 pan-head screws, as shown in Figure 3.
  • Page 4 Reinstall the handle using the supplied 4-40 × 5/16 pan-head screws, as shown in Figure 4. Reinstall the handle covers by snapping them over the handle mounting plates. 2 (4x) 2 4-40 × 5/16 pan-head screws 1 Handle covers Figure 4. Reinstalling the Handle and Handle Covers NI PMA-1115 User Guide and Specifications ni.com...
  • Page 5 1 M4 × 8 pan-head screws 1 6-32 × 3/8 flat-head screws © National Instruments Corporation Orient the chassis and PMA-1115 as shown in Figure 5. Install the remaining M4 × 8 pan-head screws. Figure 5. Installing the PMA-1115 Open the keyboard and LCD, as shown in Figure 6. Install the supplied 6-32 ×...
  • Page 6: System Configuration

    Note Do not place the AC adapter over any vent holes on the chassis cover, as this may cause chassis cooling issues. System Configuration The On-Screen Display (OSD) controls on the side of the PMA-1115 provide standby functionality, as well as standard video adjustments for the LCD.
  • Page 7: Ordering Information

    Auto-power switch ... LCD goes into standby when Power switch ... Left side of product (STDBY) Diagonal size... 15 in. (38.11 cm) Maximum resolution ... 1024 × 768 © National Instruments Corporation 1.8 A maximum no signal is present NI PMA-1115 User Guide and Specifications...
  • Page 8: Keyboard And Mouse

    Contrast ratio ...500:1 Brightness ...300 NTS Frame rate ...60 Hz (typical), Color ...16.2 M colors Viewing angle...160° up and down Control system ...On screen display Connectivity...VGA or DVI-I Keyboard and Mouse Keyboard ...105-key, English language Mouse ...Touchpad Connectivity...USB Mechanical Overall dimensions ...14.75 × 2.31 × 11 in. Weight ...5.0 kg (11 lb) LCD monitor folding angle ...Up to 80°...
  • Page 9: Operating Environment

    Relative humidity range ... 10 to 90%, noncondensing. Storage Environment Ambient temperature range... –20 to 60 °C Relative humidity range ... 10 to 90%, noncondensing. © National Instruments Corporation (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit.)
  • Page 10: Shock And Vibration

    Storage Range Shock and Vibration Operational shock ...10 g peak, half-sine, 11 ms pulse Random Vibration Operating ...5 to 500 Hz, 0.31 g Nonoperating ...5 to 500 Hz, 2.46 g NI PMA-1115 User Guide and Specifications Twb = 39 °C Operation Range Temperature (°C) Figure 8.
  • Page 11: Safety And Compliance

    To obtain the DoC for this product, visit ni.com/certification appropriate link in the Certification column. © National Instruments Corporation IEC 60950-1, EN 60950-1 UL 60950-1, CSA 60950-1 , search by model number or product line, and click the...
  • Page 12: Environmental Management

    Waste Electrical and Electronic Equipment (WEEE) At the end of their life cycle, all products must be sent to a WEEE recycling EU Customers center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit National Instruments...
  • Page 13: Where To Go For Support

    Where to Go for Support The National Instruments Web site is your complete resource for technical support. At troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504.
  • Page 14 Instruments Corporation. National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
  • Page 15 Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or ni.com/patents.

This manual is also suitable for:

Ni pxi

Table of Contents