BUILT-IN UNIT INSTRUCTION GUIDE
Please use this manual in conjunction with your main manual to properly assemble your built-in grill. Refer to
the main manual for operating, cleaning, and maintenance instructions. This grill is designed for NON-COM-
BUSTIBLE enclosures only, and must be installed and serviced by a qualified installer to local codes.
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as
shown in the built-in instructions. A flexible metal connector is included to simplify the installation of the unit. Connect this connector
to the 3/8" flare fitting on the end of the manifold. Connect the other end of the connector to the gas piping. Ensure that the
connector does not pass through a wall, floor, ceiling or partition, and is protected from damage. Do not use hose to connect the
unit. It must be connected with either rigid pipe, copper tube or an approved flexible metal connector. The installation must comply
with CAN B149.1 Natural Gas and Propane installation code in Canada, or to the National Fuel Gas code, ANSI Z223.1 in the United
States. The minimum recommended piping size is NPS 1/2" for rigid pipe, and 1/2" OD for copper tubing (based on a 20 ft run).
Longer runs may require larger sizes to conform with local codes or to conform with CAN B149.1. Propane Gas Installation Code in
Canada or to the National Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply must be connected to the 3/8" flare
elbow fitting located under the right hand side of the control panel. If installing a side burner, a separate line must be branched off to
the side burner unit and enter the side burner opening at the specified location. If the enclosure is to house a propane cylinder, the
tank portion of the enclosure must be ventilated according to local codes, and must not have communication with the cavity used to
enclose the gas grill. A propane tank can not be stored below the gas grill.
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as
shown in the built-in instructions. A flexible metal connector is included to simplify the installation of the unit. Connect this connector
to the 3/8" flare fitting on the end of the manifold. Connect the other end of the connector to the gas piping. Ensure that the connector
does not pass through a wall, floor, ceiling or partition, and is protected from damage. Do not use hose to connect the unit. It must
be connected with either rigid pipe, copper tube or an approved flexible metal connector. The installation must comply with CAN
B149.1 Natural Gas and Propane Installation Code in Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the United States.
The minimum recommended piping size is NPS 1/2" for rigid pipe, and 5/8" OD for copper tubing (based on a 20 ft run). Longer
runs may require larger sizes to conform with local codes or to conform with CAN B149.1. Natural Gas Installation Code in Canada
or to the National Fuel Gas Code, ANSI Z223.1 in the United States.
Built in units are supplied with a drip pan which holds only a minimal amount of grease. To prevent grease fires, the pan must
be cleaned after each use.
DANGER: READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING GRILL. FAILURE TO FOLLOW
THESE INSTRUCTIONS EXACTLY COULD RESULT IN A FIRE CAUSING SERIOUS INJURY OR DEATH.
THE ENTIRE INSTALLATION MUST BE LEAK TESTED BEFORE OPERATING THE GRILL.
SERIAL #______________________
N415-0175 / MAR 04/08

Advertisement

loading

Summary of Contents for Napoleon Gourmet Grill

  • Page 1 BUSTIBLE enclosures only, and must be installed and serviced by a qualified installer to local codes. BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as shown in the built-in instructions.
  • Page 2 BUILT-IN UNIT OPENING DIMENSIONS OUTDOOR GFI ELECTRICAL OUTLET RECOMMENDED - BIPT450 / BIPT600 / BIPT750 LOCATE ON LEFT SIDE OF GRILL FOR ROTISSERIE USE. 2” 34” RECOMMENDED MINIMUM 10 SQ IN OF VENTILATION REQUIRED ON EACH END OF CABINET MODEL OPENING DIMENSIONS BIPT450 1/2”...
  • Page 3 BUILT-IN ACCESSORY OPENING DIMENSIONS NOTE: ACCESSORY FRAMES OVERLAP OPENING BY 1 ½” ON ALL 4 SIDES Part # Description N370-0069 Flat vertical painted door N370-0071 Flat vertical stainless steel door Flat horizontal painted door N370-0070 N370-0072 Flat horizontal stainless steel door N370-0356SS Curved stainless steel door - 308 size N370-0357SS...
  • Page 4 1. BIPT450 BUILT-IN INSTRUCTIONS N080-0213 N080-0213 N570-0026 N715-0080 N010-0281 W445-0031 N010-0568 This grill is designed for MASONRY, NON-COMBUSTIBLE enclosures only, and must be installed and serviced by a qualified installer to local codes. 1. Attach side mounting brackets to each side of the grill using #14 x 1/2" screws (n570-0026). 2.
  • Page 5 2. BIPT600 BUILT-IN INSTRUCTIONS N080-0213 N570-0026 N080-0213 N715-0081 N380-0009 N051-0001 W445-0031 N010-0281 N010-0569 This grill is designed for MASONRY, NON-COMBUSTIBLE enclosures only, and must be installed and serviced by a qualified installer to local codes. 1. Attach side mounting brackets to each side of the grill using #14 x 1/2" screws (n570-0026). 2.
  • Page 6 3. BIPT750 BUILT-IN INSTRUCTIONS N080-0213 N570-0026 N080-0213 N715-0082 N380-0009 N051-0001 W445-0031 N010-0281 N010-0570 This grill is designed for MASONRY, NON-COMBUSTIBLE enclosures only, and must be installed and serviced by a qualified installer to local codes. 1. Attach side mounting brackets to each side of the grill using #14 x 1/2" screws (n570-0026). 2.
  • Page 7 4. BIU405 BUILT-IN INSTRUCTIONS N080-0215 N715-0083 N570-0026 N570-0026 N570-0026 N080-0215 W445-0031 N010-0281 23 e c-c N080-0155 N080-0155 This grill is designed for MASONRY, NON-COMBUSTIBLE enclosures only, and must be installed and serviced by a qualified installer to local codes. Access must be provided in the enclosure for drip tray removal and cleaning. 1.
  • Page 8 5. BUILT-IN SIDE BURNER INSTRUCTIONS 1. Fit the side burner frame into the opening. The frame should be attached to the opening to prevent any future movement (fasten- ers not included). 2. Ensure that there is at least 5 sq in of opening in the bottom of the cut out, for combustion air. 3.
  • Page 9 6. BUILT-IN ACCESSORY DRAWER INSTRUCTIONS 1. Unpack the drawer frame assembly. 2. Remove the drawers from the enclosure by fully extending them and then lifting up to remove them from the slides. 3. Shim the opening to ensure that the enclosure fits snuggly into the opening. Ensure that the side shims are located at the same height as the enclosure mounting holes.
  • Page 10 GUIDE D’INSTRUCTIONS POUR LES GRILS ENCASTRÉS Veuillez utiliser ce guide conjointement avec votre manuel principal pour assembler votre gril encastré de façon adéquate. Référez-vous au manuel principal pour connaître les instructions de fonctionnement, de nettoyage et d’entretien. Ce gril est conçu pour des cabinets INCOMBUSTIBLES seulement et doit être installé et entretenu par un installateur qualifié...
  • Page 11 DIMENSIONS D’OUVERTURE POUR LES GRILS ENCASTRÉS PRISE EXTÉRIEURE AVEC INTERRUPTEUR DE DÉFAUT À LA TERRE RECOMMANDÉE - LOCALISER SUR LE CÔTÉ CUVES DE GRIL ENCASTRÉS GAUCHE DU GRIL POUR UTILISATION AVEC LA RÔTISSOIRE. 2” 34" RECOMMANDÉ MINIMUM DE 10 PO² DE VENTILATION EST NÉCESSAIRE À...
  • Page 12 DIMENSIONS D’OUVERTURE POUR LES ACCESSOIRES LE CADRE DES ACCESSOIRES CHEVAUCHE L’OUVERTURE DE 1 ½” SUR LES QUATRE CÔTÉS. N° de pièce Description N370-0069 Porte verticale peinte N370-0071 Porte verticale en acier inoxydable N370-0070 Porte horizontale peinte N370-0072 Porte horizontale en acier inoxydable N370-0356SS Porte cambrée en acier inoxydable - modèle 308 N370-0357SS...
  • Page 13 1. INSTRUCTIONS POUR LE GRIL ENCASTRÉ BIPT450 N080-0213 N080-0213 N570-0026 N715-0080 N010-0281 W445-0031 N010-0568 Ce gril est conçu pour des cabinets INCOMBUSTIBLES OU EN MAÇONNERIE seulement et doit être installé et entretenu par un installateur qualifié selon les codes locaux. 1.
  • Page 14 2. INSTRUCTIONS POUR LE GRIL ENCASTRÉ BIPT600 N570-0026 N080-0213 N080-0213 N715-0081 N380-0009 N051-0001 W445-0031 N010-0281 N010-0569 Ce gril est conçu pour des cabinets INCOMBUSTIBLES OU EN MAÇONNERIE seulement et doit être installé et entretenu par un installateur qualifié selon les codes locaux. 1.
  • Page 15 3. INSTRUCTIONS POUR LE GRIL ENCASTRÉ BIPT750 N080-0213 N570-0026 N080-0213 N380-0009 N715-0082 N051-0001 W445-0031 N010-0281 N010-0570 Ce gril est conçu pour des cabinets INCOMBUSTIBLES OU EN MAÇONNERIE seulement et doit être installé et entretenu par un installateur qualifié selon les codes locaux. 1.
  • Page 16 4. INSTRUCTIONS POUR LE GRIL ENCASTRÉ BIU405 N080-0215 N715-0083 N570-0026 N570-0026 N570-0026 N080-0215 W445-0031 N010-0281 23 e c-c N080-0155 N080-0155 Ce gril est conçu pour des cabinets INCOMBUSTIBLES OU EN MAÇONNERIE seulement et doit être installé et entretenu par un installateur qualifié...
  • Page 17 5. INSTRUCTIONS POUR LE BRÛLEUR LATÉRAL ENCASTRÉ l. Placez le cadre du brûleur latéral dans l’ouverture. Le cadre doit être fixé à l’ouverture pour qu’il ne puisse pas bouger (pièces de fixation non comprises). 2. Assurez-vous qu’il y ait au moins 5 po² d’ouverture dans le bas de la découpe pour l’air de ventilation. 3.
  • Page 18 6. INSTRUCTIONS D’INSTALLATION DES TIROIRS 1. Déballez l’assemblage du cadre et des tiroirs 2. Retirez les tiroirs du cadre en les ouvrant complètement puis en les soulevant pour les retirer des glissières. 3. Placez des cales pour vous assurer que le cadre soit bien ajusté dans l’ouverture. Assurez-vous que les cales soient situées à...

This manual is also suitable for:

Bipt450Bipt600Bipt750Biu405Side burner