Diagrams; Circuit Boards Location; Printed Wiring Board And Schematic Diagrams Information; Reference Information - Sony Trinitron KV-29FV300 Service Manual

Hide thumbs Also See for Trinitron KV-29FV300:
Table of Contents

Advertisement

Available languages

Available languages

5-1. CIRCUIT BOARDS LOCATION

C Board
V Board
HR Board
GK Board
5-2. PRINTED WIRING BOARDS AND
SCHEMATIC DIAGRAMS INFORMATION
All capacitors are in µF unless otherwise noted. pF : µµF 50WV or less
are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms. kΩ=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating
electrical power, is as follows: Pitch : 5mm
Rating electrical power :
/
W in resistance,
/
W and
1
1
1
4
10
: nonfl ammable resistor
: fusible resistor
: internal component
: panel designation and adjustment for repair
: earth ground
: earth-chassis
All variable and adjustable resistors have characteristic curve B, unless
otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10MΩ digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production tolerances.
All voltages are in V.
S : Measurement impossibility.
: B+line
: B-line (Actual measured value may be different).
: signal path (RF)
Circled numbers are waveform references.
SECTION 5: DIAGRAMS
T Board
A Board
/
W
1
4
/
W in chip resistance.
8
The components identifi ed by shading and
only with part number specifi ed.
The symbol
indicates a fast operating fuse and is displayed on the component
side of the board. Replace only with fuse of the same rating as marked.
Les composants identifi es per un trame et une marque
securite. Ne les remplacer que par une piece portant le numero specifi e.
Le symbole
indique une fusible a action rapide. Doit etre remplace par une
fusible de meme yaleur, comme maque.
The components identifi ed by X in this basic schematic diagram have
been carefully factory-selected for each set in order to satisfy regulations
regarding X-ray radiation. Should replacement be necessary, replace
only with the value originally used.
When replacing components identifi ed by Y, make the necessary
adjustments as indicated. If the results do not meet the specifi ed value,
change the component identifi ed by X and repeat the adjustment until
the specifi ed value is achieved.
(Refer to R530 and R531 adjustment on page 16.)
When replacing the parts listed in the table below, it is important to
perform the related adjustments.
Part Replaced (
A BOARD:
R550, T503, T504, D519,
IC501, R533, D521, R532,
D520, C531, R529, R530,
R531, C532

REFERENCE INFORMATION

RESISTOR
: RN
METAL FILM
: RC
SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW
NONFLAMMABLE WIREWOUND
: RS
NONFLAMMABLE METAL OXIDE
: RB
NONFLAMMABLE CEMENT
:
ADJUSTMENT RESISTOR
COIL
: LF-8L MICRO INDUCTOR
— 29 —
KV-27FV300/29FV300/32FV300/36FV300
symbol are critical for safety. Replace
!
sont critiques pour la
!

)
Adjustment (
HV HOLD DOWN
R530, R531
CAPACITOR
: TA
TANTALUM
: PS
STYROL
: PP
POLYPROPYLENE
: PT
MYLAR
: MPS
METALIZED POLYESTER
: MPP
METALIZED POLYPROPYLENE
: ALB
BIPOLAR
: ALT
HIGH TEMPERATURE
: ALR
HIGH RIPPLE

)

Hide quick links: