Dell Latitude 7000 Series Technical Manualbook page 77

Hide thumbs Also See for Latitude 7000 Series:
Table of Contents

Advertisement

Dell Latitude 7000 Series
Operating conditions and MIL-STD 810G Testing
Performed
Models
Temperature Range
Relative humidity (maximum)
Altitude (maximum)
MIL-STD-810G Tests Performed
Link to Product Safety, EMC and Environmental Data Sheets:
http://www.dell.com/content/topics/global.aspx/about_dell/values/regulatory_compliance/dec_conform?c=us&cs=04&l=en&s=bsd&redirect=1
1
Tests completed by independent 3
77
Dell Latitude 7000 Series
Operating 0° to 35°C (32° to 95°F)
Storage –40° to 65°C (–40° to 149°F)
Operating 10% to 90% (non-condensing)
Storage 5% to 95% (non-condensing)
Operating 0 to 3048 m (0 to 10,000 ft)
Storage 0 to 10,668 m (0 to 35,000 ft)
1.
METHOD 500.5 LOW PRESSURE (ALTITUDE) Procedure I - Storage/Air Transport
2.
METHOD 500.5 LOW PRESSURE (ALTITUDE) Procedure II - Operation/Air Carriage
"METHOD 501.5 HIGH TEMPERATURE Procedure I Induced (Storage and Transition) Conditions "
3.
"METHOD 501.5 HIGH TEMPERATURE Procedure II – Operation Cycling temperature exposure"
4.
5.
METHOD 502.5 LOW TEMPERATURE Procedure I (Exaggerated)
6.
METHOD 502.5 LOW TEMPERATURE Procedure II
7.
METHOD 507.5 Procedure II Humidity Aggravated Cycle
8.
METHOD 510.5 SAND AND DUST Procedure I
1
9.
IP5x Dust Ingress Duration: 8 hours (Current result: failed)
10.
METHOD 514.6 VIBRATION Procedure I
11.
METHOD 514.6 VIBRATION Procedure I
12.
Method 516.6 SHOCK Procedure I: Functional Shock
13.
"Method 516.6 SHOCK Procedure IV: Transit Drop; Modified to be dropped at 30"""
14.
Method 516.5 SHOCK Procedure II: Material to be Packaged
15.
Method 516.5 SHOCK Procedure V: Crash Hazard Shock
16.
Method 516.6 SHOCK Procedure VI: Bench Handling
rd
party ISO/IEC-17025 certified laboratories.