Download Print this page
Murphy Diagnostic Display PV10 Specifications

Murphy Diagnostic Display PV10 Specifications

Diagnostic display

Advertisement

Quick Links

PowerView™ - Model PV10 – Diagnostic Display
Product Description
The PV10 Diagnostic display is a CAN device that receives data from a
controller or ECU and then displays Active and Stored Fault messages and
Engine Hours.
The default mode provides hourmeter data from the ECU for cumulative
engine hours.
The PV10 is equipped with two buttons to quickly select between Active or
Stored Faults, a graphic display, two LED to indicate the Active fault's Alarm
or Shutdown status in a sealed enclosure that matches the PowerView line
of gages.
Fault Messages
Fault messages are formatted to display SPN (Suspect Parameter Number), FMI (Failure Mode Indicator) and OC
(Occurrence Count) codes that conform to the SAEJ1939 protocol.
Bezel Styles
AB
A-20 Style
Features
• Display supports electronically controlled engines and
equipment applications that use SAE J1939 Controller Area
Networks.
• Displays Active and Stored diagnostic trouble codes for
diagnosing equipment malfunctions.
• Displays Engine Hours, SPN, FMI, and OC information on a
graphic display.
• Provides enhanced visual alarm indication using Ultra-bright
ALARM or SHUTDOWN LEDs (amber and red).
• Simple installation and connections to the system bus.
Rugged design for demanding applications includes backlit
display and is sunlight viewable.
A
A-20 Style
Low Profile SAE Style
BB
Low Curved Style
0810305
10-21-08
Section 78
DB

Advertisement

loading
Need help?

Need help?

Do you have a question about the Diagnostic Display PV10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Murphy Diagnostic Display PV10

  • Page 1 PowerView™ - Model PV10 – Diagnostic Display Product Description The PV10 Diagnostic display is a CAN device that receives data from a controller or ECU and then displays Active and Stored Fault messages and Engine Hours. The default mode provides hourmeter data from the ECU for cumulative engine hours.
  • Page 2: Specifications

    IP68 How to Order Warranty - A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.