System Severity Settings - D-Link DES-3528 User Manual

Xstack
Hide thumbs Also See for DES-3528:
Table of Contents

Advertisement

xStack DES-3528 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual

System Severity Settings

The Switch can be configured to allow alerts be logged or sent as a trap to an SNMP agent or both. The level at which
the alert triggers either a log entry or a trap message can be set as well. Use the System Severity Settings menu to
set the criteria for alerts. The current settings are displayed below the Settings menu. In the Configuration folder,
click System Severity Settings, to view the window shown below.
Use the drop-down menus to configure the parameters described below.
Parameter
System Severity
Severity Level
Click Apply to implement the new System Severity Settings.
Figure 6- 12. System Severity Settings
Description
Choose how the alerts are used from the drop-down menu. Select log to send the alert of the
Severity Type configured to the Switch's log for analysis. Choose trap to send it to an SNMP
agent for analysis. Select all to send the chosen alert type to an SNMP agent and the
Switch's log for analysis.
Choose what level of alert will trigger sending the log entry or trap message as defined by the
Severity Name. Select critical to send only critical events to the Switch's log or SNMP agent.
Choose warning to send critical and warning events to the Switch's log or SNMP agent.
Select information to send informational, warning and critical events to the Switch's log or
SNMP agent.
35