Diagnosis & Troubleshooting; Diagnosis; Pre-Diagnostics Checks; Diagnostics Mode - KitchenAid KSSC36FKB00 Technical Education

2001 k model built-in side-by-side refrigerator with variable capacity compressor
Hide thumbs Also See for KSSC36FKB00:
Table of Contents

Advertisement

DIAGNOSIS & TROUBLESHOOTING
Warmer
Power
On/Off
Colder

PRE-DIAGNOSTICS CHECKS

• Confirm the refrigerator and freezer tem-
peratures before beginning other checks.
• See if the compressor, evaporator, and
condenser fans are running.
• Check the position of the air door.

DIAGNOSTICS MODE

The Diagnostics Mode is used to:
• Check the refrigerator & freezer ther-
mistors.
• Operate the evaporator fan motor at 3000
rpm.
• Operate the condenser fan motor and com-
pressor.
• Check the defrost bimetal and heater.
To enter the Diagnostics Mode, the control
must be turned on, and be in a normal cooling
mode.

DIAGNOSIS

FREEZER
REFRIGERATOR
°C
SELECT
Both the Power On/Off and the Water Filter
Reset keys must be functional. The refrigera-
tor display shows the step number. The results
of the checks are displayed on the water filter
status indicator. After 20 minutes, the control
will default from the Diagnostics Mode to a
normal cooling mode.
To enter the diagnostics mode:
• Press and hold the Water Filter Reset
To advance the diagnostics sequence:
• To advance to the next step in the se-
6-1
Warmer
Colder
keypad, and then immediately press and
hold the Power keypad. Continue to press
both keypads for 3 seconds, or until you
hear a beep.
quence, press and hold the Water Filter
Reset key for 2 seconds, or until you hear
a beep. The Diagnostics Chart on the next
page shows the step number and the com-
ponent being tested in each step.
WATER FILTER
RESET
PERCENT LEFT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents