Download Print this page

Control Pads On The Dehumidifier; Control Pads; Other Features - RCA RDH505 Owner's Manual

Hide thumbs Also See for RDH505:

Advertisement

CONTROL PADS ON THE DEHUMIDIFIER

NOTE: The control panel of the unit you purchased may be slightly different according to the
models.
2
Filter
Filter
Bucket full
Full
indicator light
Cont.
Cont.
1
7
Continuous
operation on
Timer on/off
indicator light
indicator light
Fig.1

Control pads

When you push the button to change
operation modes, the unit will make
a beep sound to indicate that it is
changing modes.
Continue Pad
1
Press to activate the continuous dehumidifying
operation.
2
Filter Pad
The check filter feature is a reminder to clean the
Air Filter for more efficient operation. The Filter
light(Clean filter l ight) will illuminate after 250 hours
of operation. To reset after cleaning the filter, press
the Filter pad and the light will go off.
3
Fan Pad
Control the fan speed. Press to select either High
or Normal fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.
Clean filter
High fan
indicator light
indicator light
Turbo
Fan
Normal
Auto defrost
On
Off
Timer
6
5
4
Auto defrost operation on
indicator light
4
Power Pad
Press to turn the dehumidifier on and off.
: Down/Up Pads
5
7
Humidity Set Control Pads
The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the
pad and set to a lower
percent value(%).
For damper air, press the
pad and set a higher
percent value(%).
TIMER Set Control Pads
Use the Up/Down pads to set the Auto
start and Auto stop time from 0.0 to 24.
Timer Pad
6
Press to initiate the Auto start and Auto stop feature,
in conjuction with the
and
4
10
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
( ± 5% accuracy) room % humidity level in a range of
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position-- Empty
3
the bucket and replace it in the right position.
Low fan
indicator light

Other features

Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not replaced in the proper position.
Auto Shut Off
The
dehumidifier
shuts off after 30 seconds when
the bucket is full, or when the bucket is removed
or not replaced in the proper position.When the
setting humidity is reached, the unit will be shut
off automatically. For some models,the fan motor
will continue operating.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
Check filter feature
The system starts to count the time once the fan
motor operates. The check filter feature can be
only activated when the accumulated operation
time achieves 250 hours or more. The Reset
light(Clean filter indicator light) flashes at one time
per second, after finishing clean the air filter, press
the Filter pad and the Reset light(Clean filter indicator
light) goes off.
key pads.
CONTROL PADS ON THE DEHUMIDIFIER
EC- Unit malfuction--
Please make sure whether the
enviroment temperature is suitable for the stated
temperature in the manual or not.If not,please operate
30%
the unit under the stated temperature.If the enviroment
temperature is suitable for the stated temperature,please
call
for
service.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.
Setting the Timer
When the unit is on, first press the Timer
button, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
When the unit is off, first press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again the
Time Off indecator light illuminates.It
indicates the Auto Stop is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights illuminate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.
5

Advertisement

loading

This manual is also suitable for:

Rdh705