Electrical connection

This machine is supplied with a
connection cable without a plug for
connection to a suitable connection
socket or isolator switch.
,
The voltage, rated load and fuse
rating are given on the data plate.
Please ensure these match the site
mains supply.
This machine must be connected to the
electricity supply in accordance with
local and national safety regulations
(BS 7671 in the UK).
Connection to the electricity supply
must only be carried out by a suitably
qualified and competent person.
Connection should be made via a
suitable connection socket or isolator
which complies with local and national
safety regulations and which is easily
accessible for disconnecting the
machine from the electrical supply.
Provision must be made on site to
switch off all poles. Switches with a
minimum all-pole contact gap greater
than 3 mm are suitable for isolating the
machine. These include circuit
breakers, fuses and relays (IEC/EN
60947).
,
If the machine is disconnected
from the electricity supply ensure
adequate measures are taken to
ensure that the machine cannot be
reconnected to the electricity supply
until all work has benn carried out.
Should the connection cable require
replacing or changes be necessary in
the electrical installation including
checking and/or replacing the fuse
please make sure this is done by an
approved electrician to ensure
compliance with all local and national
electrical safety requirements.
For extra safety, it is advisable to
protect the machine with a suitable
residual current device (RCD).
WARNING:
THIS APPLIANCE
MUST BE EARTHED