Table 4-2 (continued). RS-232 communication commands.
Operation Commands (continued)
Command
Clear[y].
EDIDG[x].
EDIDM[X]B[y].
EDIDC[x]B[y].
EDIDExtract[x][y].
UpgradeSoftwareEDID[y].
EDIDUpgrade[x].
UpgradeIntEDID[x].
EDID/[x]/[y].
Page 22
Function
Clear preset command y, y=0–
11.
Get EDID data from output x
and display it on com port.
Enable input x to learn the
EDID data from output y. If the
EDID data is not available, the
matrix will set it to initial EDID
data.
Capture the EDID data of out-
put x and save it as No.y EDID,
y=1–10, 12–14
Invoke No.y EDID data saved
through COM port to input x,
y=1–10, 12–14
Save the EDID data to No.y
EDID, invoke the EDID by send-
ing command
EDIDExtract[x][y].
Upgrade the EDID data of
input x (x=1~4: upgrade the
EDID of single input; x=9:
upgrade the EDID of all inputs)
Send EDID file (.bin) within 10
seconds.
Used for programing custom-
ized EDID data x=12–14,
please refer to 4.2.4 EDID
Management for more details.
Invoke embeded EDID data
No.y to input x, y=1–10
877-877-2269 | blackbox.com
Feedback Example
Clear F1
EDIDM3B1
EDIDC3B1
Pick up success
Please send the EDID
file
Upgrade success
Please send the EDID
file
Upgrade success
Please send the EDID
file.
EDID/8/3