5. [d12] System Reset
Select the test program No. [d12] on the GAIN encoder and press the [+48V] key to reset the system and return to
normal operating mode.
You can also do this by entering the following characters:
AD8HR_DIAG>reset
from the terminal software.
2-6. Command Table
Other commands are also available in the test program. These commands are run from the terminal software.
AD8HR_DIAG> [ESC]
Displays a menu of command that can be used including test programs.
AD8HR_DIAG> 0
Starts up the auto test program. See Page 34.
AD8HR_DIAG> 1
Starts up the LED test program. See Page 38.
AD8HR_DIAG> 2
Starts up the switch test program. See Page 38.
AD8HR_DIAG> 3
Not used. (Only for factory test.)
AD8HR_DIAG> 4
Starts up the HA GAIN TRIM preset value setting (auto) program. (Execute if needed.) See Page 40.
AD8HR_DIAG> 5
Starts up the HA GAIN TRIM preset value setting (manual) program. (Execute if needed.) See Page 41.
AD8HR_DIAG> 6
Starts up the COM A/B adjustment program. See Page 39.
AD8HR_DIAG> 7
Not used. (Only for factory test.)
AD8HR_DIAG> 8
Not used. (Only for factory test.)
AD8HR_DIAG> 9
Not used. (Only for factory test.)
AD8HR_DIAG> A
Not used. (Only for factory test.)
AD8HR_DIAG> B
Not used. (Only for factory test.)
AD8HR_DIAG> C
Not used. (Only for factory test.)
AD8HR_DIAG> ver[Enter]
Displays the current program version. See Page 41.
AD8HR_DIAG> date[Enter]
Displays the date of manufacture. If the date, for example, is January 1, 2000 then the display shows, "The date of
manufacture is 2000/01/01."
However, when there is no data available, the display shows, "The date of manufacture is unknown."
AD8HR _DIAG> reset[Enter]
Resets the system. See Page 42.