Panasonic CS-W12CTP Service Manual page 89

Room air conditioner
Hide thumbs Also See for CS-W12CTP:
Table of Contents

Advertisement

TIMER TABLE
Name
Real Timer
Time Delay Safety Control
Forced Operation
Time Save Control
Anti-Freezing
Auto Mode Judgement
Soft Dry
OFF
ON
Cooling
Deodorizing Control
Soft Dry
Comp. Reverse Rotation Detection
Sleep Mode Operation
Sleep Mode Waiting
Random Auto Restart Control
4 Way Valve
After Deice Ended
Hotstart Delay Times
Hotstart Finish Times
Deice Operation Occurs (1.5 HP)
Overload Deice Timer (1.5 HP)
Deice End (1.5 HP)
Deice Operation (Extend) (1.5 HP)
Hotstart Finish (1.5 HP)
Test Mode
Time
(When test point
Short-circuited)
1 hr.
1 min.
10 min.
10 sec.
1 min.
1 sec.
2 min. 58 sec.
0 sec.
60 sec.
0 sec.
7 min.
4.2 sec.
4 min.
0 sec.
25sec.
0 sec.
6 min.
36 sec.
10 min.
60 sec.
40 sec.
4 sec.
70 sec.
7 sec.
20 sec.
2 sec.
180 sec.
18 sec.
40 sec.
4 sec.
360 sec.
36 sec.
5 min.
30 sec.
2 min.
0 sec.
8 hrs.
48 sec.
1 hr.
6 sec.
0 ~ 62 sec.
0 ~ 6.2 sec.
5 min.
30 sec.
30 sec.
3 sec.
4 min.
0 sec.
2 min.
0 sec.
60 min.
6 sec.
4 min.
24 sec.
50 sec.
0 sec.
1 min.
6 sec.
12 min.
72 sec.
30 sec.
3 sec.
10 sec.
1 sec.
60 sec.
0 sec.
120 sec.
0 sec.
180 sec.
0 sec.
30 sec.
0 sec.
89
CS-W12CTP CU-W12CTP5 / CS-W18CTP CU-W18CTP5 / CS-W24CTP CU-W24CTP5
Remarks
Soft Dry: 10 min. operation
Comp. ON 5 min. and above
Comp. OFF after deice (2.0 & 2.5 Hp)
(2.0 & 2.5 Hp)
(2.0 & 2.5 Hp)
60 min. after previous deice
Continuously 4 min. Comp. ON
TRS ON continuously for 50 sec. check
Comp. ON continuously for 1 min. check
Max. Operation time
30 sec. Comp. OFF after deice
4-Way Valve ON 10 sec. later after deice

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-w18ctpCu-w18ctp5Cu-w12ctp5Cs-w24ctpCu-w24ctp5

Table of Contents