Heat Exchanger
Description
Tube material
Fin material
Fin Type
Row / Stage
FPI
Size (W × H × L)
Refrigerant Control Device
Refrigeration Oil
Refrigerant (R410A)
Thermostat
Protection Device
Capillary Tube
Length
Flow Rate
Inner Diameter
Air Filter
Material
Style
Capacity Control
Compressor Capacitor
Fan Motor Capacitor
• • • • Specifications are subject to change without notice for further improvement.
CS-W12CTP CU-W12CTP5 / CS-W18CTP CU-W18CTP5 / CS-W24CTP CU-W24CTP5
Unit
CS-W12CTP
Evaporator
Copper
Aluminium
Louver Fin
2 × 12
mm
857 × 252 × 25.4
(c.c)
g (oz.)
Electronic Control
mm
l/min
mm
P.P.
Honeycomb
µF, VAC
µF, VAC
1.5 µF, 440VAC
7
CU-W12CTP5
Aluminium (Blue Coated)
Corrugated Fin
(Plate fin configuration, forced draft)
20
705.8 × 504 × 36.38
735.1
Capillary Tube
RB68A or Freol Alpha 68M
Overload Protector
Cooling: 850, Heating: 590
Cooling: 4.5, Heating: 8.2
Cooling: 1.1, Heating: 1.3
Capillary Tube
35 µF, 370VAC
2.0 µF, 450VAC
Condenser
Copper
2 × 24
17
(330)
1,060 (37.4)