Sony HCD-DZ555K Service Manual page 28

Hide thumbs Also See for HCD-DZ555K:
Table of Contents

Advertisement

HCD-DZ555K/DZ556KB/DZ750K
QQ
3 7 63 1515 0
(2) Select "2. Drive Manual Operation" by pressing the 2 button
on the remote commander. The screen will appear as shown.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
(3) Select "3. Manual Adjustment" by pressing the 3 button on
the remote commander. The screen will appear as shown.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
O o Change Value
[RETURN] Return to previous menu
(4)Select "6.IOP" by pressing the 6 button on the remote
commander.
TE
L 13942296513
(5) Wait until a hexadecimal number appear.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 58:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
O o Change Value
[RETURN] Return to previous menu
(6) Convert each data from hexadecimal to decimal using
conversion table.
(7) Please find the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
(8) Subtract between these two values.
(9) If the remainder is smaller than 93 (decimal), then it is OK.
However if the value is higher than 93, then the BU is defective
and need to be change.
www
(10) Press the RETURN button on the remote commander to
return back to previous menu.
.
(11) Press the 0 button on the remote commander to return to
Top Menu.
28
http://www.xiaoyu163.com
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
13-4. Emergency History
To check the emergency history, please follow the following
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select "3.
Emergency History Check" by pressing the 3 button on the
remote commander. The following screen appears on the on-
screen display.
Emg. History Check
Laser Hours
CD
DVD
01. 01 05 04 04
00 00 00 00
02. 02 02 01 01
00 00 00 00
[Next] Next Page
[Prev] Prev Page
[O] Return to Top Menu
(2) You can check the total time when the laser is turned on during
playback of DVD and CD from the above menu. The maximum
time, which can be displayed are 999h 59min.
(3) You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press . or > button on the remote
commander. The error code consists of the following three
blocks. The first block indicates the error code. The second
block indicates the parameter and the third block indicates the
Q Q
3
6 7
1 3
1 5
time of error code as shown below.
• Error Code
Emg. History Check
Laser Hours
CD
DVD
*
*
1
2
01. 01 05 04 04
00 00 00 00
02. 02 02 01 01
00 00 00 00
[Next] Next Page
[Prev] Prev Page
[O] Return to Top Menu
*1 : Error Code
*2 : Parameter of error code
*3 : Time of error code
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
co
33: TE sensor adjustment error
34: TE loop gain adjustment error
.
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
9 4
2 8
999h
59min
999h
59min
00 92 46 00
00 00 23 45
00 A9 4B 00
00 00 23 45
0 5
8
2 9
9 4
2 8
999h
59min
999h
59min
00 92 46 00
*
00 00 23 45
3
00 A9 4B 00
00 00 23 45
m
9 9
9 9

Hide quick links: