Notes When Using Service Manual - Hitachi DZ-GX3300E Service Manual

Hide thumbs Also See for DZ-GX3300E:
Table of Contents

Advertisement

Safety Precaution for Repair > Notes When Using Service Manual

1-5 Notes When Using Service Manual

(1) Value units used in parts list
Certain symbols are indicated as shown below for value units of resistors, capacitors and coils in
parts list. When you read them, note the following regular indications:
Parts
Indication in list
Resistor
KOHM .......................................... k
Capacitor
UF ................................................. F
PF .................................................. pF
Coil
UH ................................................ H
MH ................................................ mH
(2) Values in schematic diagrams
The values, dielectric strength (power capacitance) and tolerances of the resistors (excluding
variable resistors) and capacitors are indicated in the schematic diagrams using abbreviations.
Certain symbols are indicated for value units: When you read them note the regular indications in
tables below:
[Resistors]
Item
Value
No indication ................................
K.................................................... k
M ................................................... M
Tolerance
No indication ................................ ±5%
(All tolerances other than ±5% are
indicated in schematic diagrams)
Power
No indication ................................ 1/8W
capacitance
(1/16 W for leadless resistors with no
indication)
All capacitances other than the above
are indicated in schematic diagrams.
(3) Identifying sides A/B in circuit board diagrams
1) Board with pattern on one side only and parts on both sides:
Side A: Shows discrete parts.
Side B: Shows leadless parts, viewed from the pattern side.
2) Board with patterns and parts on both sides:
Side A: Shows parts and patterns which can be seen when the case is opened.
Side B: Shows the parts and the pattern on the back of side A.
Regular indication
Indication
1 - 5
[Capacitors]
Item
Value
No indication ................................ F
P .................................................... pF
Dielectric
No indication ............................... 50V
strength
(All dielectric strengths other than
50 V are indicated in schematic
diagrams)
[Coils]
Item
Value
.................................................... H
m ................................................... mH
Indication
Indication

Hide quick links: