Error Check Mode; Demand Response Operation; Procedure For Error Check Mode - Fujitsu AU*G36LRLA Service Instruction

3 phase type room air conditioner
Hide thumbs Also See for AU*G36LRLA:
Table of Contents

Advertisement

1-30-4 ERROR CHECK MODE

In this mode, abnormality that is occurring now can be confirmed.
(Table : 22 Procedure for Error Check Mode )
Procedure
Check that the "ERROR" LED blinking (Hi-speed),
1
and then short press the ENTER SWITCH 1 time.
Error code is displayed by lighting LED.
2
(Refer to Table : 21)
When the MODE SWITCH is pressed for more than
3
3 seconds, the Error history is cleared.
Note.
When the EXIT SWITCH is pressed, this mode ends and returns to the status display.
1-31. DEMAND RESPONSE OPERATION (For Aust model)
This product is designed to be compatible with Air Conditioning Demand Response program.
To utilize the function, Demand Response (DR) adapter kit that interconnects your air conditioner and
Demand Response Enabling Device (DRED) needs to be installed in your air conditioning system,
and you need a separate arrangement.
When your electricity supplier activates one of the following 3 DR modes, the air conditioner switches over to
the appropriate operation, and the OPERATION indicator (green) on the indoor unit blinks to inform you
it has been entered to the DR mode.
OPERATION indicator
(Indoor unit)
(Table : 23 Demand Response Mode )
DR mode
DR mode 1
Compressor off.
The air conditioner continues to cool or heat during the Demand Response event, but the electrical energy consumed
DR mode 2
by the air conditioner in a half hour period is not more than 50% of the total electrical energy that would be consumed
if operating at the rated capacity in a half hour period.
The air conditioner continues to cool or heat during the Demand Response event, but the electrical energy consumed
by the air conditioner in a half hour period is not more than 75% of the total electrical energy that would be consumed
DR mode 3
if operating at the rated capacity in a half hour period.
: Light OFF
: Light ON
Operation
Blinking pattern and the interval are as follows:
ON (4 seconds)
OFF (0.5 seconds)
The indicator will keep blinking until the unit finishes the function.
Notes:
Shape, number, and the arrangement of the indicators are unit-dependent.
Some indoor units may not have the indicators unless the optional control panel or
IR receiver kit has been installed.
Description of operation in this mode
01-39
2 : 2 Times Blinking
Power
Error
L1
Mode
Blinking
Hi-speed
n
2
2
2
2
Confirm Chapter 2 " TROUBLE SHOOTING" in detail.
OFF (0.5 seconds)
ON (0.5 seconds)
n : n Times Blinking
L2
L3
L4
L5
L6
n
2
2
2
2
2
L7
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents