Wired Remote Controller - Mitsubishi Electric PLA-RP35BA Operation Manual

Hide thumbs Also See for PLA-RP35BA:
Table of Contents

Advertisement

3. Operation
3.5.2 Vane·Vent. (Lossnay)
<Accessing the menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
<Vane setting>
Fri
Swing
Off
Off
Vane
Vent.
Louver
F1
F2
F3
F4
Fri
Room
Cool
Set temp.
Auto
Mode
Temp.
Fan
<Vent. setting>
Fri
Low
Vent.
F1
F2
F3
F4
<Returning to the Main menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
8
Select "Vane·Louver·Vent. (Loss-
nay)" from the Main menu (refer to
page 7), and press the [SELECT]
button.
Press the [F1] or [F2] button to go
through the vane setting options:
"AUTO", "Step 1", "Step 2", "Step
3", "Step 4", "Step 5" and "Swing".
Select the desired setting.
Auto
Auto
Step 1
Step 2
Step 3
Step 4
Step 5
Swing
Swing
Select "Swing" to move the vanes
up and down automatically.
When set to "Step 1" through "Step
5", the vane will be fixed at the se-
lected angle.
under the vane setting icon
This icon will appear when the
vane is set to "Step 5" and the
fan operates at low speed during
cooling or dry operation (depends
on the model).
The icon will go off in an hour,
and the vane setting will auto-
matically change.
Press the [F3] button to go through
the ventilation setting options in the
order of "Off", "Low", and "High".
* Settable only when LOSSNAY
unit is connected.
Off
Low
High
Off
Low
• The fan on some models of indoor
units may be interlocked with cer-
tain models of ventilation units.
Press the [RETURN] button to go
back to the Main menu.
Note:
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in "STAND BY" or "DEFROST" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
< How to set the fixed up/down air direction (Only for
wired remote controller) >
Note:
This function cannot be set depending on the outdoor unit to be
connected.
• For PLA-(Z)RP . BA and PLA-SP . BA series, only the particular outlet
can be fixed to certain direction with the procedures below. Once fixed,
only the set outlet is fixed every time air conditioner is turned on. (Other
outlets follow UP/DOWN air direction setting of remote controller.)
Explanation of word
• "Refrigerant address No." and "Unit No." are the numbers given to
each air conditioner.
• "Outlet No." is the number given to each outlet of air conditioner.
(Refer to the illustration below.)
• "Up/Down air direction" is the direction (angle) to fix.
Reset
horizontal
Horizontal airflow
Remote controller setting
The airflow direction of this outlet
is controlled by the airflow direc-
tion setting of remote controller.
Outlet No.3
High
Outlet No.2
Note: "0" indicates all outlets.
1
2
3
4
Downward
Fixed
The airflow direction of this outlet is fixed
in particular direction.
* When it is cold because of direct
airflow, the airflow direction can be fixed
horizontally to avoid direct airflow.
Outlet No.4
Outlet No.1
5
MITSUBISHI
ELECTRIC
label