Alarm Codes; Streaming Alarms - AMX NMX-ENC-1100 Instruction Manual

Hide thumbs Also See for NMX-ENC-1100:
Table of Contents

Advertisement

Alarm Codes

The following sections list the alarm codes for each alarm category.

Streaming Alarms

The following table list the Streaming alarms.
Streaming Alarms
Code
Priority
1
C
2
C
3
C
4
C
5
L
6
L
7
H
8
C
9
M
10
M
11
M
12
M
13
L
14
L
15
L
16
L
17
C
18
C
19
C
20
C
21
C
22
C
26
C
28
C
29
H
30
H
50
C
Instruction Manual - NMX-ENC H.264 Encoder
Text
Stream suspended duration [x days xx:xx:xx]
Invalid encoding parameters
Invalid arguments
Unsupported resolution
Stream started
Stream stopped duration [x days xx:xx:xx]
Input resolution changed from <current> to
<new>
Invalid video bit rate: <bitrate> [<minrate>..
<maxrate>]
Adjusted video bit rate: <bitrate> to Max:
<maxrate>
Adjusted video bit rate: <bitrate> to Min:
<minrate>
Stream audio mute disabled
Stream audio mute enabled
Timeout: Stop the record/stream
Output Resolution <scaled resolution>
UDP stream: <IP:port>
RTP stream: <IP:port>
No stream destination: Stream not allowed
Encoder stopped: Stream suspended
Encoder exited: Stream suspended duration
[x days xx:xx:xx]
Encoder restarted: Stream suspended
Stream autorestart <attempt> of <max attempts> The encoder has unexpectedly stopped and the stream will
Streaming is not permitted
No input signal: Stream not allowed
Exceeded maximum number of <max num> auto
restarts
Encoder forced restart: Too many underruns
Encoder forced restart: AV time drift
Encoder forced restart
Description
Some anomaly has suspended streaming:
• Network cables are unplugged
• Loss of input signal
Invalid parameters selected for encoding.
Input resolution is not supported by the encoder.
Stream has successfully started.
Stream has successfully stopped.
Input resolution changed to a new resolution.
The current bit rate is out of range for the input resolution.
The current bit rate was clipped to the maximum bit rate
supported for the current resolution.
The current bit rate was clipped to the minimum bit rate
supported for the current resolution.
Streaming and recording audio is unmuted.
Streaming and recording audio is muted.
The streaming or recording session failed to start.
The scaled output resolution.
Indicates the transport stream IP and port.
Indicates the RTP stream IP and port.
Neither streaming destinations are selected, therefore,
streaming is disabled.
While streaming some change in the input signal, such as
resolution or signal loss, forced the encoding engine to stop.
This will result in streaming to be suspended.
While streaming, some error condition forced the encoding
engine to stop. This will result in streaming to be suspended.
While streaming, the encoder crashed and restarted. The
stream is suspended, but will be restarted within 30 seconds.
automatically restart. This can happen <attempts> of <max
attempts> times. Currently, the Max Attempt setting is 3.
A streaming start command was received while streaming was
in a "not allowed" state.
The input signal has been disrupted causing stream to be
disabled.
Too many attempts to auto restart have been made so
streaming has been suspended.
Stream session was restarted due to too many underruns.
Stream session was restarted due to diverging audio and
video time stamps.
Encoding engine has been terminated due to lack or sluggish
response.