Don't output the laser power of 7.0mW more than 15sec.
7. Next turn the JOG DIAL to display "LDPWR CHECK".
8. Press ENTER key to display "(0.9mW)$##". Check the
laser power meter reads 0.85-0.95mW.
9. Next set range 10mW of the laser power meter, then
press ENTER key to display "(7.0mW)$##". Confirm that
the laser power meter and digital voltmeterat that time
read the specified value.
Specification :
Reading of laser power meter : 7.0
Reading of digital voltmeter : Optical pick-up indication value
±10%
(optical pick-up label)
(Optical pick-up label)
In this case, lop = 82.5 mA
In this case, lop = 82.5 mA
lop(mA) = Reading of digital voltmeter (mV)/1(Ω)
lop(mA) = Reading of digital voltmeter(mV)/1(Ω)
10. Press the ENTER key to display "LDPWR CHECK" and
stop the laser emission. (The DELETE key can be
pressed at any time to stop the laser emission.)
Note : The "#" display on the screen indicates an arbitrary
figure.
5-6. Traverse Adjustment
Connection :
X33
ADJUSTMENT
TE2
VC
Adjustment :
1. Connect the oscilloscope to (TE2) and (VC) on the X33
board.
2. Insert a commercial recordable disc.
3. Turn the JOG DIAL to display "EFBAL ADJUST".
4. Press the ENTER key to display "EFBAL MO-W" and
after that press the ENTER key again to display
"EF=$##MOW".
5. Turn the JOG DIAL so that the waveform on the oscillo-
scope satisfies the specified value. (When the JOG DIAL
is turned, the #-marked figure in "EF=$##" changes and
the waveform also changes.)During this adjustment, the
oscilloscope changes in units of about 3%. Adjust so
that the waveform comes nearest to the specified value.
(MO groove read power traverse adjustment)
(Traverse waveform)
Specification : A = B
12
CIRCUIT DESCRIPTION
±0.1 mW
KMS
260A
27x40
B0825
Oscilloscope
+
-
V: 0.5V/div H: 10ms/div
INPUT: DC mode
6. Press the ENTER key to display "EFB=##XSAVE"
momentarily. After that, "EF=$##MOR" is displayed.
(Laser power READ power, focus servo ON, tracking
servo OFF, and spindle(S) servo ON.)
7. Turn the JOG DIAL so that the waveform on the oscillo-
scope satisfies the specified value. (When the JOG DIAL
is turned, the #-marked figure in "EF-##" changes and
the waveform also changes.) During this adjustment, the
oscilloscope changes in units of about 2%. Adjust so that
the waveform comes nearest to the specified value. (MO
groove read power traverse adjustment)
(Traverse waveform)
Specification : A = B
8. Press the ENTER key to display "EFB=##XSAVE"
momentarily and save the adjustment result in non-
volatile memory After that, "EFBAL MO-P" is displayed.
9.
Press ENTER key to display "EF=$##MOP".(A pick-up
moves automatically to pit block area.)
10. Turn the JOG DIAL so that the waveform on the oscillo-
scope comes near to the specified value. During this
adjustment, the waveform changes in units of about 2%.
Adjust so that the waveform comes nearest to the speci-
fied value.
(Traverse waveform)
Specification : A = B
11. Press the ENTER key to display "EFB=##XSAVE"
momentarily and save the adjustment result in non-
volatile memory. After that, "EFBAL CHANGE" is dis-
played. The disc rotation stops automatically.
Note : The "#" display on the screen indicates an arbitrary
figure.
12. Press the EJECT key to take out a recordable disc.
13. Insert test disc TGYS-1.
14. Press the ENTER key to display "EF=$##CD". A servo
is established automatically.
15. Turn the JOG DIAL so that the waveform on the oscillo-
scope comes near to the specified value. During this
adjustment, the waveform changes in units of about 2%.
Adjust so that the waveform comes nearest to the speci-
fied value.
(Traverse waveform)