Motorola ColdFire MCF5281 User Manual page 227

Motorola microcontroller user's manual
Table of Contents

Advertisement

Table 9-10. Stop Mode Operation (Sheet 5 of 5)
MODE
In
SCM
1 0 0 On On 1
Note:
PLL = PLL enabled during STOP mode. PLL = On when STPMD[1:0] = 00 or 01
OSC = Oscillator enabled during STOP mode. Oscillator is on when STPMD[1:0] = 00, 01, or 10
MODES
NRM = normal PLL crystal clock reference or normal PLL external reference or PLL 1:1 mode. During PLL 1:1 or normal
external reference mode, the oscillator is never enabled. Therefore, during these modes, refer to the OSC = On case
regardless of STPMD values.
EXT=external clock mode
REF=PLL reference mode due to losing PLL clock or lock from NRM mode
SCM=PLL self-clocked mode due to losing reference clock from NRM mode
RESET= immediate reset
LOCKS
'LK= expecting previous value of LOCKS before entering stop
0–>'LK= current value is 0 until lock is regained which then will be the previous value before entering stop
0–> = current value is 0 until lock is regained but lock is never expected to regain
LOCS
'LC=expecting previous value of LOCS before entering stop
1–>'LC= current value is 1 until clock is regained which then will be the previous value before entering stop
1–> =current value is 1 until clock is regained but CLK is never expected to regain
MOTOROLA
Expected
PLL
PLL Action
Action at
During Stop
Stop
Lose reference
clock
Chapter 9. Clock Module
MODE
Out
SCM
0
0
SCM
Functional Description
Comments
1
9-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Coldfire mcf5282

Table of Contents