Table 9-10. Stop Mode Operation (Sheet 5 of 5)
MODE
In
SCM
1 0 0 On On 1
Note:
PLL = PLL enabled during STOP mode. PLL = On when STPMD[1:0] = 00 or 01
OSC = Oscillator enabled during STOP mode. Oscillator is on when STPMD[1:0] = 00, 01, or 10
MODES
NRM = normal PLL crystal clock reference or normal PLL external reference or PLL 1:1 mode. During PLL 1:1 or normal
external reference mode, the oscillator is never enabled. Therefore, during these modes, refer to the OSC = On case
regardless of STPMD values.
EXT=external clock mode
REF=PLL reference mode due to losing PLL clock or lock from NRM mode
SCM=PLL self-clocked mode due to losing reference clock from NRM mode
RESET= immediate reset
LOCKS
'LK= expecting previous value of LOCKS before entering stop
0–>'LK= current value is 0 until lock is regained which then will be the previous value before entering stop
0–> = current value is 0 until lock is regained but lock is never expected to regain
LOCS
'LC=expecting previous value of LOCS before entering stop
1–>'LC= current value is 1 until clock is regained which then will be the previous value before entering stop
1–> =current value is 1 until clock is regained but CLK is never expected to regain
MOTOROLA
Expected
PLL
PLL Action
Action at
During Stop
Stop
—
—
Lose reference
clock
Chapter 9. Clock Module
MODE
Out
SCM
0
0
SCM
Functional Description
Comments
1