1J-15 Charging System:

Charging System Specifications

Battery
Battery
: 55B24R (42.5AH/5HR) 12V
Battery type
Rated Capacity
AH/5HR, 12 Volts
Electrolyte
L (US/Imp. pt)
Electrolyte S.G.
Generator
Type
Rated voltage
Nominal output
Permissible max. speed
No-load speed
Setting voltage
Permissible ambient
temperature
Polarity
Rotation

Tightening Torque Specifications

Fastening part
"B" terminal nut
Generator mounting bolt
Generator pivot bolt
NOTE
The specified tightening torque is also described in the following.
"Generator Unit Components"
"Generator Components"
Reference:
For the tightening torque of fastener not specified in this section, refer to "Fasteners Information in Section 0A".

Specifications

55B24R
42.5
2.8
(5.92/4.93)
1.28 when fully charged at 20 °C (68 °F)
80 A type
12 V
80 A
18000 r/min (rpm)
1200 r/min (rpm)
14.2 to 14.8 V
–30 to 100 °C (–22 to 212 °F)
Negative ground
Clockwise viewed from pulley side
N⋅m
5
25
52.5
Tightening torque
kgf-m
lb-ft
0.5
4.0
2.5
18.5
5.25
38.0
S6RW0C1A07001