Hitachi 27MMV30B Service Manual page 5

Solid state color tv
Table of Contents

Advertisement

TECHNICAL
CAUTIONS
HV Protection
circuit operation
checking.
Hiah voltaae
limiter circuit operation
check and over voltaae
protection
circuit operation
check.
Adjustment
Preparation
(1) Connect a high voltage voltmeter between CPT anode terminal (Anode cap side) and the ground as below.
(2) Set AC input voltage to 120&3V.
(3) Receive Hitachi circle pattern and set "Bright" and "CONTRAST" to max. Adjust Screen VR so that Beam
Current is 1 B 1 .15&O. 1 mA. (The voltage of ABL terminal-C725
both ends should be 12V or less)
CPT
\
High
voltage
voltmeter
(DC
voltage
divider)
ital
voltmeter
GND WIRE
Use
the
voltmeter
Of
input
impedencelOM
ohm
or more
with
indication
to the
1st
decimal
place.
Adiustment
Procedure
(1) Check that the normal High Voltage is 27.0+1.5KV and +B Voltage is 130+1.5V.
(2) Connect jig A to the Both end of R706 and check that the power is turned off.
D706
+56V 0-w
To D718
4-s-J
jig=kR
1/8W
w
3
c725
Less than 12V
0.1150
(3) Disconnect the AC plug and remove jig A.