Power Board Voltage Measuring Method - LG 42LB5800 Service Manual

Led
Hide thumbs Also See for 42LB5800:
Table of Contents

Advertisement

Standard Repair Process Detail Technical Manual
symptom
LCD TV
Copyright ⓒ 2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Error
A. Video error_No video/ Audio
A Video error No video/ Audio
t
Content

Power Board voltage measuring method

The Wafer,18Pin and 24Pin, is used by operating LocalDimming or not LocalDimming
- 24Pin wafer is applied operating L/D at power and main B/D
- 18Pin wafer is applied not operating L/D at power and main B/D
Established
date
Revised
date
Check the DC 24V, 12V, 3.5V.
18 or 24 Pin
(Power Board ↔ Main Board) -
SMAW200-H18/24S5 (YEONHO)
1
PWR ON/OFF
3
3.5V
5
3.5V
7
GND
9
9
24V
24V
11
GND
13
12V
15
12V
17
17
GND
GND
19
GND
21
GND
23
L/DIMO_MOSI
18 / 97
2014 1 2
2014.1.2
공통
2
INV ON
4
PDIM #1
6
3.5V
8
PDIM #2
10
10
24V
24V
12
GND
14
12V
16
24V or N.C
18
18
GND
GND
20
GND
22
L/DIMO_VS
24
L/DIMO-SCLK
LGE Internal Use Only