Symptom
The present time, preset timer
settings, and elapsed Keep Warm
time are lost when the power plug is
disconnected.
The lid will not open, or it opens
during cooking.
Nothing happens when a key is
pressed.
Sparks fly from the power plug.
There is a smell of plastic.
There are stripes or waves on plastic
parts.
Bubbles can be seen coming from
the steam vent of the steam cap
during cooking.
The lid cannot be closed.
Food adheres to the inner lid during
concurrent cooking.

If these indications appear

Display
"Err" appears on the display and a long-
lasting or continuous beeping alarm
sounds.
Plastic parts
Plastic parts that come into contact with heat or steam will deteriorate over time. In this case, contact the
place of purchase.
Check point
Does "0:00" blink on the display
when the power plug is connected
again?
Are there any grains of rice adhering
to the upper casing, inner lid gasket,
or around the open/lock button?
Is the power plug properly connected
to an outlet?
Is the Keep Warm lamp on?
Inserting/disconnecting the power plug may sometimes cause small electric
sparks. This is specific to the IH feature and therefore not a malfunction.
Such smells may occur when the rice cooker is first used, but they should
go away over time as the rice cooker gets used.
Such stripes and waves are produced when the resin is being molded.They
do not affect the performance of the rice cooker.
It is due to boiling and therefore not a malfunction.
Is the inner lid attached?
When cooking with ingredients that expand during heating, such as eggs
and the like, some of that may adhere to the inner lid. If it is bothersome,
reduce the amount of the ingredients.
If the rice cooker is placed on the carpet or where the room
temperature is high, the air inlet and outlet can be blocked, causing
the temperature inside to rise. In this case, the rice cooker may not
respond to any key operations. Resolve the problem according to the
following procedure.
(1) Disconnect the power plug.
(2) Relocate the rice cooker to where the air inlet and outlet are not
blocked and the room temperature is low.
(3) Insert the power plug into the outlet again and operate the keys.
If the rice cooker does not respond to key operations, it is a malfunction
of the rice cooker. Disconnect the power plug and contact the place of
purchase.
Action
The lithium battery has run out.
Contact the place of purchase.
Completely remove all remaining
rice.
Insert the power plug fully into an
outlet.
Press the [Cancel] key to turn off the
Keep Warm function, then try the
operation again.
Attach the inner lid.
Action
Reference
page
12
16,
36-41
17
17
38
Reference
page
47