HP NC570C User Manual page 54

Dual-port 4x fabric adapter
Hide thumbs Also See for NC570C:
Table of Contents

Advertisement

42
# cat /proc/scsi/scsi
Attached devices:
Host: scsi0 Channel: 00 Id: 00 Lun: 00
Vendor: SEAGATE
Type:
Direct-Access
Host: scsi0 Channel: 00 Id: 01 Lun: 00
Vendor: SEAGATE
Type:
Direct-Access
Host: scsi2 Channel: 00 Id: 00 Lun: 00
Vendor: DGC
Type:
Direct-Access
Host: scsi2 Channel: 00 Id: 00 Lun: 01
Vendor: DGC
Type:
Direct-Access
Host: scsi2 Channel: 00 Id: 00 Lun: 02
Vendor: DGC
Type:
Direct-Access
# cat /proc/scsi/srp/2
Topspin SRP Driver
Index
Service
0
T10.SRP5006016810201173
IOC GUID
00:05:ad:00:00:01:1e:d8
Number of Pending Connections 0
Number of Active Connections 1
Number of Connections 1
srp_host: target_bindings=5006016810201173.0
Verify SRP Functionality
To show the SCSI devices that are currently visible from the SRP host:
Example of CX200
Model: ST336706LC
Model: ST336706LC
Model: RAID 1
Model: RAID 5
Model: RAID 5
a.
Note the following LUNs are visible, but cannot be accessed, (which is appropriate for this
set-up).
Host: scsi2
Channel: 00
Id: 00
Lun: 00/01
b.
Note the following LUN is the CX200 RAID-5 group, which is available to the IB host:
Host: scsi2
Channel: 00
Id: 00
Lun: 02
Verify the SCSI HCA Driver Information
The following examples show verification of an EMC CX200 configuration from the SRP host.
1.
Verify the SCSI HCA driver instance information that is associated with the SRP driver:
Example of CX200
fe:80:00:00:00:00:00:00:00:05:ad:00:00:01:29:81
64 256 255
Rev: 010A
ANSI SCSI revision: 03
Rev: 010A
ANSI SCSI revision: 03
Rev: 0099
ANSI SCSI revision: 04
Rev: 0099
ANSI SCSI revision: 04
Rev: 0099
ANSI SCSI revision: 04
Active Port GID

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nc571c

Table of Contents