Sony HCD-GN700 Service Manual page 23

Hide thumbs Also See for HCD-GN700:
Table of Contents

Advertisement

QQ
3 7 63 1515 0
RFAC Level Check
Connection:
CD board
TP5 (RFAC)
TP7 (DVC)
Procedure:
1.
Connect an oscilloscope to test point TP5 (RFAC) and TP
7(DVC) on the CD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Confirm that oscilloscope waveform is clear and check RFAC
signal level is correct or not.
Note: A clear RFAC signal waveform means that the shape "◊" can be
clearly distinguished at the center of the waveform.
RFAC signal waveform
Checking Location: CD board (SIDE B)
TE
L 13942296513
www
.
http://www.xiaoyu163.com
oscilloscope
+
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level: 0.9 ± 0.4 Vp-p
(See page 24.)
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
E-F Balance Check
Connection:
CD board
TP7 (DVC)
Procedure:
1.
Connect an oscilloscpe to test point TP2 (TE) and TP7 (DVC)
on the CD board.
2.
Turn the power on.
3.
Select the function "CD".
4.
Press three buttons of
[SURRUUND MODE]
mode.
5.
Put the disc (YEDS-18) in to playback the number five track.
.
6.
Press the
displayed. (The tracking servo and the sledding servo are turned
OFF)
7.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse Waveform
Q Q
3
6 7
1 3
1 5
0V
.
8.
Press the
displayed. (The tracking servo and sledding servo are turned
ON)
Confirm the C (DC voltage) is almost equal to the A (DC
voltage) is step 5.
9. To exit from this mode, perform as follows.
1) Move the optical pick-up to the most inside track.
2) Press three buttons of
simultaneously. (cold reset)
Notes: • Always move the optical pick-up to most inside track when
exiting from this mode. Otherwise, a disc will not be unloaded.
• Do not run the sled motor excessively, otherwise the gear can
be chipped.
Traverse Waveform
0V
co
Checking Location: CD board (SIDE B) (See page 24.)
.
HCD-GN700/GX8800
9 4
2 8
oscilloscope
TP2 (TE)
+
[ENTER]
,
M
, and
simultaneously to set the CD service
button. The message "TRAVERSE" is
B
0 5
8
2 9
9 4
2 8
level: 1.0 ± 0.5 Vp-p
button. The message "TRAVERSE" is
[CLEAR]
x
,
, and
Tracking servo
Tracking servo
m
Sled servo
Sled servo
OFF
ON
9 9
Center of
the waveform
9 9
A (DC
voltage)
[DISPLAY]
C (DC
voltage)
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcd-gx8800

Table of Contents