11:00
Ultralight vacuum cleaner
Please read and keep these
instructions
getting the best from
your new cleaner...
If your cleaner isn't picking up as
well as it should, please check
• Dustbag
It is important to replace them when full, otherwise the
performance of the cleaner will be impaired
• Filters
It is important that the filters are cleaned and replaced
regularly to allow air through the appliance
• Blockages
Check the hose for blockages
• Belt
Check and replace damaged or broken belt
Page 1
www.morphyrichards.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultralight vacuum cleaner and is the answer not in the manual?

Questions and answers

Summary of Contents for Morphy Richards Ultralight vacuum cleaner

  • Page 1 8607 Upright ib 73303 29/07/2003 Ultralight vacuum cleaner getting the best from your new cleaner... If your cleaner isn’t picking up as well as it should, please check • Dustbag It is important to replace them when full, otherwise the performance of the cleaner will be impaired •...
  • Page 2: Important Safety Instructions

    • Repairs to electrical appliances are only to be undertaken by trained personnel. Unprofessional repairs can be dangerous for users. • Use only genuine Morphy Richards spare parts and accessories • Never over-extend the hose such that the cleaner is pulled over. If the cleaner is knocked over, switch off before attempting to upright.
  • Page 3 8607 Upright ib 73303 29/07/2003 Ê ‰ „ ‚ · Á Accessories included Furniture brush Features ⁄ Upper handle ¤ Flexible hose ‹ Main body › Furniture brush fi Hose connector fl Crevice nozzle ‡ Nested extension tubes (2) · Carpet height adjustment knob ‚...
  • Page 4: Using Attachments

    8607 Upright ib 73303 29/07/2003 Assembly Warning: Do not plug in the cleaner until it is assembled. 1 Carefully unpack all components. 2 Lift cleaner body to upright position. 3 Remove the two screws that are already attached to the body. 4 From the rear of the cleaner, align the handle with groove and slide into the body.
  • Page 5 8607 Upright ib 73303 29/07/2003 Dust bag condition When the cleaner is switched on, if the dust bag condition indicator is continuously showing red (or if the suction is reduced) the bag must be replaced and the filters cleaned. If it is still showing red after emptying the dust bag and cleaning the filters, check to see if the hose is blocked.
  • Page 6: Changing The Belt

    If the power brush stops rotating it is likely that the drive belt has snapped (usually because the brush has been stalled). A spare belt is supplied. Replacement belts can also be obtained from Morphy Richards or a Service Agent. Removing the floor nozzle cover 1 Disconnect the cleaner from the mains supply.
  • Page 7: Safety Cut-Out

    8607 Upright ib 73303 29/07/2003 Safety cut-out If the cleaner overheats a motor protection thermostat will automatically switch the motor off. If this happens, switch the cleaner off, unplug from the power supply and leave the cleaner to cool for at least 30 minutes.
  • Page 8 (or authorised dealer). 4 Where the appliance has been used for hire purposes or non-domestic use. 5 Morphy Richards are not liable to carry out any type of servicing work, under the guarantee. 6 Consumables such as bags, filters and belt are not covered by the guarantee.