Power-Up Self-Check Diagnostics And Repair (Not For Field Use); Table 4-5. Power-Up Self-Check Diagnostic Actions - Motorola APX 3000 Detailed Service Manual

Hide thumbs Also See for APX 3000:
Table of Contents

Advertisement

Troubleshooting Procedures: Power-Up Self-Check Diagnostics and Repair (Not for Field Use)
4.5

Power-Up Self-Check Diagnostics and Repair (Not for Field Use)

Table 4-5
lists additional action items that can be used for the diagnosis and resolution of the error
codes listed in
Error Code/ Error
Message
01/02
01/12
01/20
01/22
01/81
01/82
01/88
01/90
01/92
01/93
01/98
01/A2
02/81
02/88
02/90
09/10
09/90
Hardware board
failed
Hardware board
mismatch
Table
4-4.

Table 4-5. Power-Up Self-Check Diagnostic Actions

This non-fatal error will likely recover if the radio's power is cycled. In the event that this
does not resolve the issue, the radio should be reflashed. If the error remains, send the
radio to depot.
The radio should be sent to the depot for reflashing of the security codeplug.
Cycling radio power should resolve this issue.
The radio should be sent to the depot for reflash of the tuning codeplug followed by
retuning of the radio.
The radio should be sent to the depot for reflashing of the host code.
The radio should be sent to the depot for reflashing of the radio codeplug.
Reflashing of the radio should first be performed. If this fails to resolve the issue, send
the radio to depot.
Cycle power to radio. Continued failure indicates a likely IC failure In this event, radio
should be sent to the depot for isolation and repair of the problem IC.
The radio should be sent to the depot for reprogramming of the security codeplug.
The radio should be sent to the depot for reflashing of the host code.
Send radio to the depot.
The radio should be sent to the depot for reflashing of the tuning codeplug followed by
re-tuning of the radio.
The radio should be sent to the depot for examination.
Cycle power to the radio. If this does not fix the problem, then the radio should be sent
to the depot for reflashing of the DSP code.
Cycle power to the radio. If this fails to fix the problem, then the radio should be sent to
the depot for reflashing of the DSP code.
Cycle power to the radio. If this fails then follow instructions in the secure hardware
failure troubleshooting flowchart.
Cycle power to the radio. If this fails then follow instructions in the secure hardware
failure troubleshooting flowchart.
Bluetooth error. Send radio to depot for examination.
Updating the firmware should resolve the error message.
Diagnostic Actions