Faults Cc-D4 - GE GFWS2500 Technical Service Manual

Louisville built front load washer
Table of Contents

Advertisement

Faults CC-D4

Fault
Name
Code
Hex
CC, CD,
IMC Fault
CE, CF
D0
Basket Strike
Detected
D1
Phase Current Error Motor phase current
D2
Locked Rotor
D3
Hall Sensor Fault
D4
IMC Communica-
tion Fault
Description
IMC Fault
Basket hit side panel.
exceeds 4.5 amps for
more than 5 minutes.
Locked Rotor
Issue with pulses from
the hall sensor.
Inverter failed to
receive a valid commu-
nication for 10 seconds.
Repair Action
• Reset IMC by unplugging washer for 30
seconds. Attempt to operate Drain and Spin
cycle.
• Enter Service Mode and check that fault has
cleared.
• If fault persists, or unit does not spin, replace
IMC (Inverter Machine Control).
• Unbalanced issue.
• Wash load too heavy.
• Item caught between tubs.
• Check the motor and basket is free to spin.
• Reset IMC by unplugging washer from
• 30 seconds. Attempt to operate a Drain and
Spin cycle.
• Enter Service Mode and check that fault has
cleared.
• Check harness and motor connections.
• If fault persists, or unit does not spin, replace
IMC (Inverter Machine Control).
• Reset IMC by unplugging washer from 30
seconds. Attempt to operate a Drain and Spin
cycle.
• Enter Service Mode and check that fault has
cleared.
• If fault persists or unit does not spin, check
hall sensor harness and module.
• If hall sensor and harness check OK, replace
IMC (Inverter Machine Control).
• Reset control boards by unplugging the
washer for 30 seconds.
• Check the wiring between the IMC and UI
boards.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents